摘要
进行了钢管混凝土(CFST)柱-钢筋混凝土(RC)环梁节点的静载和低周反复荷载实验研究,分析了节点的破坏形态、延性和耗能能力等性能.试验结果表明,这种节点连接可靠,具有良好的延性和耗能能力,能够满足延性抗震设计的要求.
Based on the experimental investigation of concrete filled steel tubular(CFST) column-reinforced concrete(RC) ring beam joints under static loading and quasi-static cyclic loading,the failure pattern,ductility and energy-dissipation capacity of the joints were analyzed.The test results reveal that the kind of joints can efficiently transfer the internal forces of beams to CFST columns,and has better ductility,energy-dissipation capacity,and can meet the requirements of ductile seismic resistant design.
引文
[1]廖旺青.钢管混凝土柱在民用建筑中的应用[J].国外建材科技,2006,26(4):135-137.
[2]高力人,方鄂华,钱家茹.高层建筑结构概念设计[M].北京:中国计划出版社,2005.
[3]CECS28-90钢管混凝土结构设计与施工规程[S].
[4]DB J13-51-2003钢管混凝土结构技术规程[S].
[5]钱稼茹,周栋梁,方小丹.钢管混凝土柱-RC环梁节点及其应用[J].建筑结构,2003,33(9):60-62;72.
[6]方小丹,李少云,钱稼茹.钢管混凝土柱-环梁节点抗震性能的试验研究[J].建筑结构学报,2002,23(6):10-18.
[7]周栋梁,钱稼茹,方小丹,等.环梁连接的RC梁-钢管混凝土柱框架试验研究[J].土木工程学报,2004,37(5):7-15.
[8]李少云,方小丹,杨润强.广州市翠湖山庄工程钢管混凝土柱节点足尺静载试验研究[J].土木工程学报,2001,34(6):11-16.
[9]黄汉炎,梁宇行,李曦新,等.钢管混凝土柱、RC梁板节点拟静力三向加载的试验研究[J].建筑结构学报,2001,22(6):3-13.
[10]凌育洪,宋欣.实用可靠的钢管混凝土柱环梁节点[J].哈尔滨工业大学学报,2004,36(10):1 378-1 381.
[11]戎长军,吴正民,苏亚武,等.钢管混凝土柱新型梁柱节点-环梁节点[J].施工技术,2004,33(4):28-30.
[12]GB/T700-2006碳素结构钢[S].
[13]杨芳.钢管混凝土柱-钢筋混凝土环扁梁中节点抗震性能的研究[D].福州:福州大学,2006.
[14]JG J101-96建筑抗震试验方法规程[S].
[15]朱伯龙.结构抗震试验[M].北京:地震出版社,1989.