乌什地震台DSQ水管倾斜仪资料干扰初步分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
对DSQ水管倾斜仪近2年的资料进行了初步分析,总结了现阶段影响DSQ水管倾斜仪资料的干扰因素。微气流及大风对水管倾斜仪存在较大干扰,造成数据曲线有较多的毛刺、台阶和抖动,但不会改变固体潮总体变化形态,采用细沙、苯板填埋堵塞电缆沟的方法后干扰有所减少。伸缩仪的检修工作、仪器自身工作状态不正常、人为进山洞也会对水管倾斜仪产生干扰。突然停电会对水管仪数据造成台阶干扰;雷雨天气、气压突变会造成水管仪资料数据曲线发生畸变。
The author analyzed the observation data of DSQ tiltmeter in recent 2 years preliminarily,summarized main interference factors influencing DSQ tiltmeter.The result showed that micro air flow and gale could affect water tube tiltmeter obviously,cause burrs,steps and wobble,but could not change the general shape of solid tide,the above inference may reduce after filling or stuffing the cable ditch with silver sand or EPS Planks;the troubleshooting for extensometer,abnormal working state of DSQ tiltmeter,artificial entering the observation cave affected the observation data quality of DSQ tiltmeter;sudden power cut could cause 1 step in the observation;thunderstorm,sudden atmospheric pressure change could affect the data seriously and make the observation curves distortion.
引文
[1]李永振.铁岭地震台数字化水管仪资料分析[J].形变学科通讯,2007,(2):45-50.
    [2]陈耿琦,于天龙,尹传兵.DSQ型水管倾斜仪安装中的一些技术问题[J].大地测量与地球动力学,2007,27(6):153-155.
    [3]张荣挺,于沈平.DSQ水管倾斜仪和SS-Y伸缩仪观测条件建设要点[J].东北地震研究,2002,18(1):66-68.
    [4]邱永平.地震前兆数字化仪器受到强雷暴干扰研究[J].地震地磁观测与研究,2003,24(5):100-105.
    ①武汉地震科学仪器研究院.DSQ型水管倾斜仪原理、安装与使用,2006,1-15.