粘滞液体阻尼器用于非对称双塔连体结构的消能减震分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
在连接体位置设置粘滞液体阻尼器对非对称双塔连体结构进行消能减震,对粘滞液体阻尼器设置的位置和阻尼系数进行了优化并对连体结构进行时程分析。计算结果表明,当阻尼器选择合适的安装位置和优化阻尼系数时,粘滞阻尼器可大量耗散地震能量,能够有效降低结构在地震作用下的振动反应。
The viscous fluid dampers are used at the location of the connecting part to dissipate energy and reduce the vibration of the non-symmetric two-tower-connected structure.The damping coefficient and installation position of the dampers are optimized to calculate the time-history analysis of the structure.The results show that the structural vibration energy can be dissipated and the vibration response induced by earthquake can be reduced efficiently by selecting appropriate locations and applying optimal damping coefficient.
引文
[1]周云.复杂耗能减震加固技术与设计方法[M].北京:科学出版社,2006.
    [2]周云.粘滞阻尼减震结构设计[M].武汉:武汉理工大学出版社,2006.
    [3]GB 50011-2001建筑抗震设计规范[S].北京:中国建筑工业出版社,2008.
    [4]Xu YL,He Q,Ko J M.Dynamic response of damper-connected ad-jacent buildings under earthquack excitation.Engineering Struc-tures,1999,21:135-148.
    [5]刘绍峰,施卫星.相邻结构连接阻尼器的最优设计参数[J].地震工程与工程振动,2007(10):166-171.
    [6]魏琏,郑久建,韦承基,薛彦涛.论粘滞阻尼减震结构及其抗震设计方法[J].建筑结构,2004(10):10-16.