通过低周反复试验研究了采用全螺栓连接、柱壁加设柱壁套管式节点的抗震性能。试验以方钢管柱、H型钢梁制作足尺节点试件,研究在反复荷载作用下节点的工作性能及破坏情况,结合试验测量数据,分析柱壁套管与方钢管柱的协同工作性能和剪力传递机制。试验结果表明:柱壁套管式节点剪力传递路径及机理明确,柱壁套管能够很好地提高节点区的抗弯承载力,并能与方钢管柱共同受力、协调变形,节点具有良好的抗震性能。总结了影响柱壁套管式节点抗震性能的主要因素及施工中应该注意的问题,为其工程推广应用提供指导。
The pseudo-static tests were carried out on column joint with outer-sleeve and bolt connection to study seismic behavior of the joint. The full-scale joint specimens of square tubular steel column and H-shaped steel beam were produced in the test. The working behavior and failure condition of the joint under cyclic loading were studied. The coordinated working behavior and shear transfer mechanism of the outer-sleeve and square tubular steel column were analyzed combined the test data. The test results show that the shear transfer way and mechanism of the joint are clear. The outer-sleeve can improve the flexural bearing capacity of the joint and works with the square tubular steel column cooperatively in force and deformation coordination. The joint has well seismic behavior. The main factors influencing the seismic behavior of column joint with outer-sleeve and problems that should pay attention to in the construction were summarized,providing guidance for the engineering applications.
引文
[1]MAHIN S A.Lessons from damage to steel building during the Northridge earthquake[J].Engineering Structures,1998,20(4-6):261-270.
    [2]宋振森,顾强,郭兵.刚性钢框架梁柱连接试验研究[J].建筑结构学报,2001,22(2):53-57.
    [3]刘其祥,蔡益燕,朱知信,等.多高层房屋钢结构梁柱刚性连接节点的抗震设计[J].建筑结构,2001,31(8):9-12.
    [4]WHITTAKER A,GILANI A,BERTERO V.Evaluation of Pre-Northridge steel moment-resisting frame joints[J].The Structural Design of Tall Buildings,1998,7:263-283.
    [5]姚开明.方钢管柱H钢梁的柱壁套管式节点性能研究[D].天津:天津大学,2008.
    [6]朱赢.钢结构柱壁套管式节点试验研究与分析[D].昆明:昆明理工大学,2013.
    [7]邱法维,钱稼茹,陈志鹏.结构抗震实验方法[M].北京:科学出版社,2000.
    [8]周天华,何保康,陈国津,等.方钢管混凝土柱与钢梁框架节点的抗震性能试验研究[J].建筑结构学报,2004,25(1):9-16.
    [9]林于东,林杰,宗周红.低周反复荷载作用下矩形钢管混凝上柱与钢梁连接节点的受力性能[J].地震工程与工程振动,2004,24(4):62-69.
    [10]李黎明,陈志华,李宁.柱壁套管式梁柱节点抗震性能的试验研究[J].地震工程与工程振动,2007,27(1):46-53.
    [11]李黎明,李自刚,陈以一.冷弯方钢管与H型钢梁柱壁套管式节点抗震性能研究[J].工业建筑,2008,38(增刊):1392-1397.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心