多层砌体房屋顶层空旷时顶层地震力的上限
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
多层砌体房屋顶层空旷少墙时,该层地震剪力可能较大。本文以振型分解反应谱抗震计算方法和结构振动理论为基础,探讨这种情况时地震作用的某些规律,给出顶层地震剪力上限值的实用计算方法。
When the top floor of a tier masonry is more soft than the rest, the seismic response in this floor may be greater. Based on mode superposition response spectrum method and structural vibration theory, upside soft tier masonries were studied, some traits of seismic response for this kind of buildings were proposed, and also, a practical method of seismic response′s maximum in top floor for upside soft tier masonry is given.
引文
[1] 苑振芳,等- 砌体结构设计手册( 第二版)[ M] .北京:中国建筑工业出版社,1992-
    [2] 施岚青( 主编)- 实用砌体结构设计手册[M]- 北京:冶金工业出版社,1990-
    [3] R- W- 克拉夫,J- 彭津- 结构动力学[ M],科学出版社,1981 .
    [4] 赵福顺,赵玉星- 下刚上柔多层砌体房屋地震作用的讨论[J]- 工程力学,1999,增刊