高层隔震建筑地震响应分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
利用Etabs软件,对某高层隔震建筑进行非线性时程分析。时程分析表明:在8度(0.3g)中震作用下,隔震结构与非隔震结构相比,隔震层以上最大减震系数为0.34,减震效果明显;在8度(0.3g)罕遇地震下,隔震结构整体抗倾覆验算满足要求;在罕遇地震作用下,隔震层发生较大变形,隔震层以上楼层层间位移很小,上部结构呈现平动。
The nonlinear time history analysis of a isolated tall building was carried out with Etabs.Time history analysis showed that the maximum of discount rates on the superstructure of the isolated structure was 0.34 under medium earthquake of 8 degree(0.3g) and damping coefficient was obvious compared to the non-isolated structure.Calculation of stability against overturning under the rare earthquake of 8degree(0.3g) was taken and met the requirement.Under the rare earthquake,story displacement of isolation layer was great and story displacement on the superstructure was small,which show that the drift of superstructure take on translational motion.
引文
[1]日本建筑学会.刘文光译.隔震结构设计[M].北京:地震出版社,2006.
    [2]王曙光,刘伟庆,冯陈.宿迁市府苑小区某商住楼隔震设计[J].世界地震工程,2001,17(4):139-142.
    [3]程华群,刘伟庆,王曙光.高层隔震建筑设计中隔震支座受拉问题分析[J].地震工程与工程振动,2007,27(4):161-166.
    [4]GB50011-2010.建筑抗震设计规范[S].
    [5]北京金土木软件技术有限公司,中国建筑标准设计研究院.ETABS中文版使用指南工程[M].北京:中国建筑工业出版社,2009.
    [6]CECS126:2001.叠层橡胶支座隔震技术规程[S].
    [7]JGJ3-2010.高层建筑混凝土结构技术规程[S].

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心