钢结构地震作用取值的讨论
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
《建筑抗震设计规范》(GB50011—2010)中钢结构地震作用取值略有调整,但是仍不甚合理。本文对规范GB 50011—2010中钢结构地震作用取值的问题进行了分析,并且和《建筑工程抗震性态设计通则》(试用)(CECS 160:2004)地震作用的取值进行了比较,对规范GB 5001 1—2010地震作用取值提出了建议。
Although the value derived from seismic action for steel buildings defined in the Code for seismic design of buildings(GB 50011—2010) has been adjusted slightly,but it is still not very reasonable.The question of how to define the value derived from seismic action for steel buildings was analyzed for code(GB 50011—2010),and comparison of the seismic action for steel buildings was made between General rule for performance-based seismic design of buildings(CECS160:2004) and code GB 50011—2010.Some design recommendations have been proposed for rationalize the definition seismic action value.
引文
[1]戴国莹.《工业与民用建筑抗震设计规范》修订简介(二)[J].工程抗震,1985(2):39-43.
    [2]刘大海,杨翠如,曾凡生,等.建筑抗震设计的新概念-对《建筑工程抗震性态设计通则》的理解[J].建筑结构,2006,36(1):89-95.
    [3]王广军.抗震规范中结构影响系数C的应用与变迁[J].四川建筑科学研究,1990(4):20-26.
    [4]叶列平,方鄂华.关于建筑结构地震作用计算方法的讨论[J].建筑结构,2009,39(2):1-7.
    [5]CECS 160—2004建筑工程抗震性态设计通则(试用)[S].北京:中国计划出版社,2004.
    [6]何若全,顾强,孙国华.关于钢结构抗震设计中结构影响系数的讨论[J].苏州科技学院学报:工程技术版,2004,17(4):29-32.
    [7]顾强,何若全,苏明周.钢结构的地震作用[J].苏州科技学院学报:工程技术版,2005,18(2):1-5.