摘要
针对近断层地震动特征,以火电厂冷却塔为例,建立了三维有限元模型。选取多条近断层地震动记录作为地震动输入,采用时程分析方法对冷却塔进行地震反应分析,分析了含速度脉冲和无速度脉冲地震动输入下的结果,并与一般地震动作用下的结果进行了对比分析。结果表明,该类构筑物对近断层地震动作用较为敏感,近断层处冷却塔的地震破坏影响程度更大。
According to characteristics of near-fault ground motions,A 3D finite element model is established for cooling tower in power plant.Multi-strip seismic motion record is selected for inputs.Seismic analysis has been made for cooling tower by time history analysis method.Results has been analyzed under input of velocity pulse records and no velocity pulse records,comparative analysis has been made for results under general seismic action,indicating that this kind of structures are sensitive under the near-fault earthquake motion effect.The influence degree under seismic damage was even larger in near fault area.
引文
[1]Hall J F,Heaton T H,Halling M W,et al.Near-source ground mo-tion and its effects on flexible buildings[J].Earthquake Spectra,1995,11(4):569-605.
    [2]Liao W I,Loh C H,Wan S.Earthquake response of RC momentframes subjected to near-fault ground motions[J].The StructuralDesign of Tall Buildings,2001,10:219-229.
    [3]Malhotra P K.Response of buildings to near-field pulse-like groundmotions[J].Earthquake Engineering and Structural Dynamics,1999,28:1309-1326.
    [4]Akkar S,Yazgan U,Gulkan P.Drift estimates in frame buildingsubjected to near-fault motions[J].Journal of Structural Engineer-ing,2005,131(7):1014-1024.
    [5]李爽,谢礼立.地震动参数及结构整体破坏相关性研究[J].哈尔滨工业大学学报,2007,39(4):505-560.
    [6]刘启方,袁一凡,金星,等.近断层地震动的基本特征[J].地震工程与工程振动,2006,26(1):1-10.
    [7]翟长海,谢礼立.估计和比较地震动潜在破坏势的综合评述[J].地震工程与工程振动,2002,22(5):1-7.
    [8]邱敏.地基—群桩—高层建筑结构在地震作用下的动力相互作用分析[D].西安:西安理工大学,2007.
    [9]Feng Z L,Lewis R W.Optimal estimation of in-situ ground stressfrom displacement measurements[J].Journal of Geotechnical andGeoenvironmental Engineering,1987,21(11):15-20.
    [10]曹晓研,李晓莉,李立新,等.桩土—结构相互作用地震反应分析[J].世界地震工程,2004,20(1):90-94.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心