防屈曲耗能钢板墙在抗震加固中的应用
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
介绍了位移型阻尼器消能减震结构在多遇地震下的计算分析方法.针对某框架结构,布置16组防屈曲耗能钢板墙加固改造,采用ETABS2013软件进行了多遇地震快速非线性分析和罕遇地震静力弹塑性分析.通过比较分析结果,多遇地震下防屈曲耗能钢板墙屈服耗能,提高结构阻尼比,降低地震力的输入,结构层间位移角有所减小并满足规范要求.罕遇地震下结构抗震性能显著提升.
The effective analytic way provided for the calculation of energy dissipation structure of displacement- based dampers under frequent earthquakes was introduced in this thesis. According to the frame structure,an 16 buckling restrained steel plate shear wall was arranged to retrofit it. In addition, the ETABS2013 was adopted to carry on the fast nonlinear analysis under frequent earthquakes and static elastic-plastic analysis under severe earthquakes. By comparing the results of analysis,the buckling restrained steel plate shear wall can yield energy dissipation under frequent earthquakes. As a result of increasing structural damping ratio and decreasing the input of seismic force,the story drift was decreased and met the standard requirement and the anti- seismic property was significantly improved under severe earthquakes.
引文
[1]中华人民共和国建设部.建筑抗震设计规范(GB50011-2010).北京:中国建筑工业出版社,2010.
    [2]程选生,贾传胜,杜修力.消能减震技术在结构抗震加固改造中的应用[Z].土木工程学报,2012,45(1):253-257.
    [3]北京金土木软件技术有限公司,中国建筑标准设计研究院.ETABS中文版使用指南[M].第1版.北京:中国建筑工业出版社,2004:464.
    [4]杨溥,李英民,赖明.结构时程分析法输入地震波的选择控制指标[J].土木工程学报,2000,33(6):33-37.
    [5]曲哲,叶列平,潘鹏.建筑结构弹塑性时程分析中地震动记录选取方法的比较研究[J].土木工程学报,2011,44(7):10-20.
    [6]ATC-63 Quantification of Building Seismic Performance Factors[J].Redwood City:Applied Technology Council,2008.
    [7]Freeman SA,Nicoletti JP,and Tyrrell JV.Evaluation of Existing Buildings for Seismic Risk[J].A Case Study of Puget Sound Naval Shipyard,Bermerton,Washington.Proceedings of the 1st U.S.National Conference on Earthquake Engineering,1975:113-122.