任楼煤矿隐伏导水陷落柱的快速判识与探查
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
1996年任楼煤矿首采面曾因隐伏导水陷落柱突水,引发淹井灾害,造成3.5亿元的重大经济损失。治水复矿后,1999年又在7218工作面机巷迎头出现淋水,初始水量不大,但依据水温、水质快速判识突水通道是隐伏导水陷落柱,运用物探和钻探相结合的综合探查方法确定了陷落柱位置,为地面布孔注浆彻底封堵陷落柱提供了保证,避免了一次重大突水淹井事故。
Because of water outburst by hidden conducting Karst collapse column at the mining area of Renlou coal mine, the flood was caused in 1996, which causes losses up to 3.5 hundred million yuan. In 1999 when reconstruction, the dripping appeared on the tunnel of 7_218 work face. Though initially flow was not much heavy,the hidden conducting Karst collapse column was still recognized by the temperature and property of the water. Then the position of the column had been determined with synthetic detecting methods, which enabled it fully filled from the surface and avoided a terrible accident.
引文
[1] 胡有彪.模糊综合评判方法在矿井水源判别中的应用,全国矿井水文工程地质学术交流会论文集[C].北京:地震出版社,1992.
    [2] 中国统配煤矿总公司生产局.煤炭科技情报研究所[Z].煤矿水害事故典型案例汇编(内部资料),1992.
    [3] 元刚.综合立体勘探在矿井水文地质勘探中的应用.中国煤矿防治水技术经验汇编[C].北京:煤炭工业出版社,1999.
    [4] 王经明,段中稳.任楼煤矿水源判别模型的自动识别系统[J].煤田地质与勘探,1996,(4):38-40.
    [5] 王经明.岩溶型煤矿岩体质量分级及其在突水评价上的应用[J].中国岩溶,2000,(3):239-245.
    [6] 王经明.承压水沿底板的梯进导升机理及其应用[J].岩土工程学报,1999,21(5):546-550.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心