小天都气垫调压室洞壁围岩原地承载力的水力劈裂测试
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
本文给出了该气垫调压室勘探平洞的水力劈裂测试结果。分析表明 ,随着洞深与埋深的增大 ,愈向山体内部岩体结构的完整性及其自身的承载能力愈趋增强。在 0 + 72 9m的第五测点 ,所有测段岩体抗劈裂强度的平均值为 7 4MPa。因此 ,该点具备修建气垫调压室要求的岩体力学条件 ,该点附近的洞段是布置气垫调压室较理想的位置。
The measurement results of the hydraulic splitting test for the bearing capacity of surrounding rock of the air-cushion surge tank are presented in this paper.Its analysis indicates that the rock structure integrality and its bearing capacity are better as the tunnel is deeper into the mountain, especially at the 5th site 0+729m,the average value of resisting split is 74MPa,and it reaches the rock mechanics qualification and provides an ideal position for building the air-cushion surge tank.
引文
[1] 谷兆祺,彭守拙,李仲奎地下洞室工程[M],北京:清华大学出版社,1994.
    [2] SL2592水利水电工程钻孔压水试验规程[S].北京:水利电力出版社,1992
    [3] 中国地震局地壳应力研究所,日本电力中央研究所.水压致裂裂缝的形成和扩展[M],北京:地震出版社,1999.
    [4] RutqvistandStephansson.AcyclicHydraulicJackingTesttoDeterminethein siteStressNormaltoaFracture[J],InternationalJournalofRockMechanicsandMiningSciences,1996,33(7).
    [5] 刘世明,胡宝磊.天荒坪抽水蓄能电站岔管区域高压渗透试验[J],地下工程技术,1996,1.
    [6] 谷兆祺等.挪威水电工程经验介绍[M],挪威:TAPIA出版社,1985.
    [7] 郭启良,安其美,赵仕广.水压致裂压力测量在广州抽水蓄能电站设计中的应用研究[J],岩石力学与工程学报,2002,21(6):828~832.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心