干式变压器抗震数值建模分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
建立准确描述体系动力特性的有限元模型是应用反应谱理论进行抗震计算的关键,以公司SCB10-800/6.3变压器为例,建立了干式变压器本体及外壳结构的有限元模型,计算了体系的模态并与实验结果进行了比较,分析了建立干式变压器抗震模型的关键问题。
The key problem of the seismic calculation based on the response spectra theory is to set up the finite element model which can deseribe the dynamic behavior of the system accurately.Taking the SCB10-E-800/6.3 transformer of Pearl electric Co.Ltd.as and example,the finite element model of main part and crust of the dry type transformer was set up.The modes were calculated and compared to the experimental results.The key problems of building dry type transformer aseismatic model were analyzed.
引文
[1]朱福寿,贾建刚,崔育忠.核电站1E级聚酰胺纸非包封干式变压器[J].变压器,2009,46(6):21-23.
    [2]刘洪峰.自耦变压器抗震计算[J].变压器,2008,45(5):16-17.
    [3]Nobuo Murota,Maria Q Feng,Gee Yu Liu.Earthquake simulator testing of base-isolated power transformers[J].IEEE Transactions on Power De-livery,2006,21(3):1291-1299.
    [4]郭振岩.变压器抗地震性能的研究[J].变压器,2005,42(8s):13-31.
    [5]Bellorini S,Salvetti M,Bettinali F,Zafferani G.Seismic qualification of transformer high voltage bushings[J].IEEE Transactions on Power Deliver-y,1998,13(4):1208-1213.
    [6]李子国,景丽英.S7-20010变型变压器抗震分析[J].地震工程与工程振动,1997,17(4):99-105.