锚定式方钢管混凝土柱与钢梁节点抗震性能试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
通过低周反复加载试验对6个锚定式方钢管混凝土柱-H形钢梁节点进行了试验研究,研究了不同轴压比情况下节点的破坏模式、延性、耗能性能、强度及刚度退化等。试验结果表明,破坏之前节点具有良好的滞回性能、延性及耗能能力,满足现行抗震规范的要求。锚定式方钢管混凝土梁柱节点可以用于拉力较小的节点。文中提出了有关的设计建议。
A total of 6 connections with anchorages for concrete filled square steel tubes with different axial compression force ratios have been tested under low-cyclic reversed loading at the end of column to research the failure modes,ductility,energy dissipation capacity and degradations of strength and stiffness.The experimental results demonstrate that all the specimens have well hysteretic behavior,ductility and energy dissipation capacity before failure.And this kind of joint meets the requirements of the current code for seismic design of buildings.The beam-to-column connection with anchorages for concrete filled square steel tube can be used for connections with minor tension.Additional seismic design recommendations are presented.
引文
[1]韩林海,钢管混凝土结构[M].北京:科学出版社,2000.
    [2]韩林海,杨有福.现代钢管混凝土结构技术[M].北京:中国建筑工业出版社,2004.
    [3]Ricles J M,Peng S W,Lu L W.Seismic behavior of composite filled steel tube column-wide flange beam moment connections[J].Journal ofStructural Engineering,ASCE,2004,130(2):223-232.
    [4]Kang Changhoon,Shin Kyungjae,Oh Youngsuk,et al.Hysteresis behavior of CFT column to H-beam connections with external stiffeners andpenetrated elements[J].Engineering Structures.2001,23(9):1194-1201.
    [5]Shin Kyungjae,Kim Youngju,Oh Youngsuk,et al.Behavior of Welded CFTColumn to H-beam Connections with External Stiffeners[J].Engi-neering Structures,2004,26(13):1877-1887.
    [6]Wu Laiyun,Chung Laploi,Tsai Shengfu,et al.Seismic behavior of bolted beam-to-column connections for concrete filled steel tube[J].Jour-nal of Constructional Steel Research.2005,61(10):1387-1410.
    [7]吕西林,李学平,余勇.方钢管混凝土柱与钢梁连接的设计方法[J].同济大学学报,2002,30(1):1-5.
    [8]周天华,何保康,陈国津,等.方钢管混凝土柱与钢框梁节点的抗震性能试验研究[J].建筑结构学报,2004,25(1):9-16.
    [9]宗周红,林于东,陈慧文,等.方钢管混凝土柱与钢梁连接节点的拟静力试验研究[J].建筑结构学报,2005,26(1):77-84.
    [10]王来,王铁成,邓芃.方钢管混凝土框架内隔板节点抗震性能的试验研究[J].地震工程与工程振动,2005,25(1):76-80.
    [11]CECS159:2004,矩形钢管混凝土结构技术规程[S].
    [12]钟善桐.高层钢管混凝土结构[M].哈尔滨:黑龙江科学技术出版社.1999.
    [13]唐九如.钢筋混凝土框架节点抗震[M].南京:东南大学出版社,1999.
    [14]JGJ101-96,建筑抗震试验方法规程[S].
    [15]赵鸿铁.钢与混凝土组合结构[M].北京:科学出版社,2001.
    [16]GB50011-2001,建筑抗震设计规范[S].