260t级硐室爆破地震测试及降震分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
根据爆破地点的地形、地质、环境条件和工程要求,通过合理地设计条形药包硐室爆破的爆破方案、爆破参数、爆破网路和微差间隔时间,较好地解决了硐室爆破震动大带来的灾害。B lastm ateⅢ型振动监测仪的测试结果表明,爆破降震取得了比较好的效果,达到了设计的预期要求。
According to the terrain,the geology,environmental condition and engineering request of the project,the scheme,parameters,initiation network and millisecond delay intervals of the chamber blasting with linear charges were designed rationally,so that the possible earthquake disaster induced by the blasting was avoided.The results obtained by use of model Blastmate Ⅲ vibration monitoring instrument indicated that the effect of vibration reduction measures was better,the expected requirement of design had been achieved.
引文
[1]邰鹏,东兆星.控制爆破技术[M].中国矿业大学出版社,2004:106~109.
    [2]三迟清扶,桶口岩雄.遂道爆破振动对策[J].铁道技术研究报告,1997,(12):1064.
    [3]GB6722———2003[S].爆破安全规程.
    [4]焦永斌,陈绍潘.首钢大石河铁矿千吨级定向抛掷硐室大爆破[J].工程爆破,2004,(9).

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心