脱硫塔的强度和稳定性有限元分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
利用有限元软件ANSYS的APDL对吸收塔进行参数化建模。考虑自重,风载荷,地震载荷,对吸收塔进行强度和稳定性分析。结果表明:吸收塔为大型薄壁构件,塔体结构发生失效的主要表现形式不是强度不足时发生的大面积塑性变形或断裂,而是垂直方向的轴向压应力导致的局部失稳。在满足稳定性要求的前提下,塔体的强度一般是满足要求的。因此,导致局部失稳的轴向力应作为重点校核对象。
Parametric FEA model is established for desulfurizer by APDL.The structure is analyzed for strength and stability under combined load of weight,wind and seismic load.It is found that maximum stress occurs at the corner of the rectangular opening for smoke entrance,and large stress also occurs at the lower part of the tower for hydraulic pressure of lime liquid and bending due to wind and seismic loads.With the extension of stability evaluation principle of cylinder under combined load,a criterion is suggested with probability of wind and seismic load in consideration to evaluate the stability of the desulfurizer.In conclusion,the desulfurizer satisfies both strength and stability requirement with the design dimensions.
引文
[1]中华人民共和国机械工业部.JB4732-95,钢制压力容器—分析设计标准[S].北京:机械工业出版社,1995.
    [2]郑津洋,董其伍,桑芝富.过程设备设计第一版[M].北京:化学工业出版社,2001.
    [3]贺匡国.压力容器分析设计基础[M].北京,机械工业出版社,1995.
    [4]余伟炜,高炳军.ANSYS在机械与化工装备中的应用第一版[M].北京:中国水利水电出版社,1998.
    [5]宋维源,刘锡昌,李吉.空心滚动体的强度分析[J].辽宁工程技术大学学报:自然科学版,1994,13(3):224-226.
    [6]殷琳,薛嵩,盛宏玉.考虑桩-土-结构相互作用的脱硫塔动力特性分析[J].安徽建筑工业学院学报:自然科学版,2007(2):115-117.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心