地下管线的爆破振动安全试验与监测
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
以南水北调中线京石段工程为例,分析了工程爆破施工区附近的供水、供气管线抗振特性,并结合现场爆破振动试验和施工监测,研究了爆破地震波的传播衰减规律和爆破振动对供水管线安全的影响。研究结果有助于确定地下管线的爆破振动安全标准,指导类似工程施工。
Regarding the emergency water supply project for Beijing-Shijiazhuang section in mid-route of South-to-North Water Diversion Project,the present paper discussed the anti-vibrating characteristic of water delivery and gas supply pipeline nearby the blasting construction.Propagation attenuation rule of blasting seismic wave and safety influence of blasting vibration on water pipeline were studied by field testing and monitoring of blasting vibration.The research results were helpful for confirming safety standard of blasting vibration on underground pipeline,giving guidance to similar engineering.
引文
[1]中华人民共和国标准.爆破安全规程(GB6722-2003)[S].北京:中国标准出版社,2004.
    [2]中华人民共和国标准.中国地震烈度表(GB/T 17742-1999)[S].北京:中国标准出版社,1999.
    [3]中华人民共和国标准.建筑抗震设计规范(GB 50011-2001)[S].北京:中国建筑工业出版社,2001.
    [4]中华人民共和国电力行业标准.水电水利工程爆破施工技术规范(DL/T 5135-2001)[S].北京:中国电力出版社,2002.
    [5]中华人民共和国石油天然气行业标准.输油(气)钢质管道抗震设计规范(SY/T 0450-2004)[S].北京:石油工业出版社,2004.
    [6]中华人民共和国国务院令(第313号)石油天然气管道保护条例[S].2001.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心