框架结构中现浇楼梯的抗震性能分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
本文研究了框架结构的楼梯在汶川地震中出现的多种震害状况,如梯段板的断裂,框架角柱的短柱破坏,楼梯间梯柱、平台梁和平台板等构件的破坏。结合《建筑抗震设计规范(GB 50011-2001)》部分规定和工程中楼梯的设计方法,分析了震害出现的原因,指出了GB 50011-2001规范中有关楼梯设计方法和构造措施的不足,给出了今后框架结构中楼梯设计和施工的相关建议。
The article studies damage of the Cast-in-place stairs of frame structures in Wenchuan earthquake, such as ladder board fracture, short column failure of corner column, damage of constructional column, platform beam and plate failure and etc. Based on the 2001 edition of the code for seismic design of building regulations and the design method of stair in engineering, we analyze the cause of the earthquake damage, show weaknesses of the stairs design method and construction measure in the old code, and put forward some suggestions about stair design and construction in the future.
引文
任彧,2009.楼梯系统对于框架抗震性能的影响.福建建筑,129(3):42—44.
    沈靓,2010.汶川地震中建筑物典型震害分析与数值计算.合肥:合肥工业大学土木与水利工程学院.
    苏启旺,蔡宏儒,李力等,2008.从“汶川大地震”引发对板式楼梯设计的思考.四川建筑科学研究,34(4):165—167.
    王奇,马宝民,2002.钢筋混凝土现浇楼梯对整体结构的影响.建筑结构,32(4):27—29.
    王亚勇,2008.汶川地震建筑震害启示——抗震概念设计.建筑结构学报,29(4):20—25.
    尹保江,黄世敏,程绍革等,2008.汶川地震中建筑楼梯震害原因分析.见:汶川地震建筑震害调查与灾后重建分析报告.北京:280—284.
    中华人民共和国国家标准,2001.建筑抗震设计规范(GB50011-2001).北京:中国建筑工业出版社.
    中华人民共和国国家标准,2010.建筑抗震设计规范(GB50011-2010).北京:中国建筑工业出版社.