长短腿直线输电塔抗震性能反应分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
采用SAP2000有限元分析软件通过对等长腿输电塔和长短腿输电塔在地震作用下的动力时程反应进行分析。比较几种输电塔结构的抗震动力响应,计算结果表明:长短腿铁塔较等长腿铁塔,整体刚度大,控制点处位移小,顶点速度、加速度小,短腿处轴力大;越往塔顶,减少同样的长度,控制点位移的每次减少量越来越小,顶点速度、加速度的每次减少量越来越小,短腿处轴力的每次增量越来越小。
Based on the finite element software SAP2000,the estimating seismic responses transmission towers with unequal legs by time-history method have been analysed,and the conclusion has been made as follow: Tower of equal legs is larger than tower of unequal legs on the overall stiffness and axis force of shot legs,but is smaller on displacement of control point and speed and acceleration of vertex;Reduction of the same length,control point displacement,the vertex speed,acceleration of each reduction is more and more smaller and short legs at each increment of axial force is getting smaller and smaller.
引文
1李宏男,石文龙.大跨越高压输电塔体系抗震分析几个关键问题研究[C].防震减灾工程研究与进展———全国首届防震减灾工程学术研讨会论文集,2004:1-6.
    2尹荣华,李东亮,刘戈林,等.高压输电塔震害及抗震研究[J].世界地震工程,2005,23(1).
    3胡大柱.地震作用下输电铁塔破坏模式分析[D].沈阳:沈阳建筑工程学院,2004:48-51.
    4瞿伟廉,殷惠君,陈波.输电线路动力分析的多质点模型研究[J].华中科技大学学报,2003,20(2):1-5.
    5沈国辉,孙炳楠,何运祥,等.大跨越输电塔线体系的地震响应研究[J].工程力学,2008,25(11):212-217.
    6杨付刚,胡启平,孙建梅.多点输入下大跨越输电塔结构抗震性能时程分析[J].电力建设,2010,31(4):1-4.
    7付鹏程,邓洪洲,吴静.输电塔动力特性研究[J].特种结构,2005,22(1):47-49.
    8GB50260-96,电力设施抗震设计规范[S].
    9GB50545-2010,110kV~750kV架空输电塔线路设计规范[S].
    10GB50011-2001,建筑抗震设计规范(2008年版)[S].
    11潘旦光,楼梦麟,范立础.多点输入下大跨度结构地震反应分析研究现状[J].同济大学学报,2001,29(10):1213-1219.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心