地震计仪器噪声测量中的几个问题
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
研究了地震计仪器噪声测量中的几个问题,并从理论、模型仿真和测量实验3个方面证实了下述结论:①平稳地噪声中,两台并列地震计的通频带差异、灵敏度差异及阻尼系数差异对测量结果没有影响;②非平稳的地背景噪声和干扰必然引起测量误差;③地震计自身噪声测量必须在安静的台基上进行。
Several issues about the measurement of a seismometer's self-noise are researched and the conclusions are: (1) The difference of the pass-band width, the sensitivity and the damping coefficient of the aligned seismometers has no influence on the measurement result. (2) Transient disturbance will cause measurement error. (3) The measurement of a seismometer's self-noise must be carried out in a noiseless station.
引文
[美]安艺敬一,P G 理查斯.1986. 定量地震学--理论和方法[M].北京:地震出版社
    Peter W. Rodgers. 1992. Frequency Limits For Seismometers As Determined From Signal-To-Noise Ratios. Part 2. The Feedback Seismometer. [J]. BSSA, 82(2) : 1 099-1123

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心