触发电路是SmartSeis R浅层地震仪的重要组成部分,同时也是故障高发部分,生产中,经常因该电路损坏而影响施工进程。本文从电路的工作原理着手,分析了该电路存在的问题,并针对问题提出了相应的电路改造方案。
Trigger circuit is an important composition part of SmartSeis R shallow seismograph, and also is a part of easy damage. The construction process is often affected by the circuit damage in production. Starting from the working principle of the circuit, the paper analyzed the existed problems of the circuit and presented relevant reforming circuit scheme according to concrete problems.