火电厂悬吊煤斗结构限位铅阻尼器耗能减震问题研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
对设置铅阻尼器的火电厂悬吊煤斗结构的耗能减震性能进行了研究。首先用解析方法分析了一个双自由度悬吊体—阻尼器结构的地震反应。然后基于地震弹塑性时程计算方法,通过设计具有不同屈服点的双线性屈服模型,分析了设置有铅阻尼器的煤斗悬吊结构的地震反应。计算结果表明,铅挤压式阻尼器对控制悬吊煤斗与结构的相对位移、减小火电厂的结构地震反应有显著的效果。
It is studied that the seismic properties of suspending coal hopper structure with lead dampers in thermal power plant.Firstly,the seismic response of a two freedom suspending structure with dampers is analyzed by an analytical approach.Then based on the calculation method of elasto-plastic time history analysis,the seismic response of the suspending coal hopper structure with lead dampers is analyzed by designing different yield-points of bilinear yielding model.The result indicates the extruded lead dampers have a distinct effect on controlling relative displacement between suspending coal hopper and structure and reducing the seismic response of the thermal power plant.
引文
1 GB 50011-2001建筑结构抗震规范.
    2常兆中,周锡元,姚德康.设置阻尼器的火电厂框架-支撑结构的减震性能分析.建筑科学,2003(12):31-33
    3周云,徐赵东,邓雪松.铅粘弹性阻尼器的计算模型建筑结构学报,2000(3):120-124
    4王艳武,王铁英,王焕定,等.两类铅阻尼器试验研究.地震工程与工程振动,2004(2):166-171
    5常业军,程文襄,隋杰英,等.钢筋混凝土框-剪结构采用粘弹性阻尼器的减震设计.东南大学学报,2002(9):733-736

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心