重复荷载作用下碳纤维约束混凝土加卸载准则
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
对12个碳纤维约束混凝土棱柱体试件(100×100×300)进行了重复荷载受压试验,分析了重复荷载作用下碳纤维约束混凝土加载及卸载应力-应变曲线的特征,基于试验结果的回归分析,建立了加卸载准则的数学表达式。分析预测与试验结果的比较证明了所提出的加卸载准则的准确性及适用性,为轴力和往复水平荷载作用下碳纤维约束混凝土柱的非线性分析提供了材料的滞回本构模型。
A total of 12 FRP-confined concrete specimens(100×100×300) with different wrap thickness and concrete strength were tested in uniaxial compression under different levels of loading and unloading.The character of loading and unloading curves was analyzed.Based on a regression analysis of test results,the mathematic expression of cyclic rules for loading and unloading are developed.The proposed model is accurate and validated by comparing analytical predictions with experimental results and the cyclic model could be easily used in nonlinear analysis of FRP-confined concrete column subjected to axial and cyclic lateral load.
引文
[1]SHAO Y.Behavior of FRP-confined concrete beam-columns undercyclic loading[D].USA:North Carolina State University,2003.
    [2]SHAO Y,ZHU Z,MIRMIRAN A.Cyclic modeling of FRP-confinedconcrete with improved ductility[J].Cement&Concrete Composites.2006,280:959-968.
    [3]LAM L,TENG J G,CHEUNG C H,et al.FRP-confined concreteunder axial cyclic compression[J].Cement&Concrete Composites.2006,28:949-958.
    [4]J FERNANDO SIMA,PERE ROCA,CLIMENT MOLINS.Cyclicconstitutive model for concrete.Engineering Structure[J].2008,30:695-706.
    [5]ILKI A,KUMBASAR N.Behavior of damaged and undamagedconcrete strengthened by carbon fiber composite sheets[J].StructureEngineering Mechanic,2002,13(1):75-90.
    [6]过镇海,张秀琴.反复荷载作用下混凝土的应力应变全曲线的试验研究[J].冶金建筑,1981:46-54.
    [7]吴波,马忠诚,欧进萍.高温后混凝土在重复荷载作用下的应力-应变关系[J].地震工程与工程振动.1997,17(3):36-43.
    [8]MANDER J B,PRIESTLY,PARK R.Theoretical stress-strain modelfor confined concrete[J].Journal of Structure Engineering,ASCE.1988,114(8):1804-1826.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心