城市供水管网泄漏频谱与预警参数研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
以傅里叶变化为理论方法,系统地研究了供水管网泄漏传播规律和泄漏噪音的频谱,提出了以供水管网泄漏的最小噪音水平为主参数,泄漏噪音的频谱、带宽以及泄漏噪音强度分布为辅助参数的供水管网泄漏和爆管判别与预警标准.这些泄漏预警参数的有效性通过广州市花都区自来水公司的实测数据得到了验证,取得了满意的效果.
This paper systematically researches on the propagation characteristics and noise spectrum of water leakage by utilization of Fourier transform methodology,and it puts forward a criteria of Minimum Noise Level as key parameter and noise spectrum,the band and noise intensity distribution as auxiliary parameters to judge or early warn water leakage or pipe burst of water distribution network. The effectiveness of these parameters is verified by the site monitoring datum of water distribution network of Guangzhou Huadu Water Utility.
引文
[1]马力辉,崔建国.供水管网检漏技术与漏损控制模型研究[J].科技情报开发与经济,200(13):129-130.MA Li-hui,CUI Jian-guo.Study on leakage detecting techniques of water supply pipe network and leakage controlling model[J].Sci-Tech Information Development&Economy,200(13):129-130.(in Chinese)
    [2]陈玲俐,李杰.供水管网渗漏分析研究[J].地震工程与工程振动,2003(23):115-121.CHEN Ling-li,LI Jie.Leakage analysis of water supplying networks[J].Earthquake Engineering and Engineering Vibration,2003(23):115-121.(in Chinese)
    [3]余娟,王典洪,唐伯良.一种结合DFT和FFT的使用傅里叶变换算法[J].计算机应用与软件,2005(22):38-39,116.YU Juan,WANG Dian-hong,TANG Bo-liang.One useful fourier transform algorithm combining FFT with DFT[J].ComputerApplications and Software,2005(22):38-39,116.(in Chinese)
    [4]邢丽娟,杨世忠.压电加速度测量系统的设计[J].压电与声光,2009,31(2):215-217.XING Li-juan,YANG Shi-zhong.Design for piezoelectric accelerometer measurement system[J].2009,31(2):215-217.(in Chinese)
    [5]何芳,刘遂庆.供水管网爆管事故分析与对策探讨[J].管道技术与设备,2004(5):20-23.HE Fang,LIU Sui-qing.Analysis on pipe break in water distribution system and its countermeasures[J].Pipeline Techniqueand Equipment,2004(5):20-23.(in Chinese)
    [6]POULAKIS Z,VALOUGEORGIS D,PAPADIMITRIOU C.Leakage detection in water pipe networks using a Bayesianprobabilistic framework[J].Probabilistic Engineering Mechanics,2003,18(4):315-327.
    [7]张宏伟,牛志广.城市供水管道漏损预测模型研究[J].中国给水排水,2001,17(6):7-9.ZHANG Hong-wei,NIU Zhi-guang.Study on the prediction model for water supply net leakage[J].China Water&Wastewater,2001(6):7-9.(in Chinese)
    [8]孙立国,周玉文.基于压电传感器与GSM技术的供水管网漏损控制系统[J].中国给水排水,2010,26(6):1-4.SUN Li-guo,ZHOU Yu-wen.Research onwater distribution system leakage control and early warning parameters based onpiezoelectric sensors and GSM communication technology[J].China Water&Waste Water,2010(3):1-4.(in Chinese)

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心