嵌筋墙体抗剪破坏机理分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
嵌筋加固是一种新型后配筋砌体的墙体加固技术。根据高宽比为0.5和1.8的嵌筋加固墙体试验结果,对其破坏形式和破坏机理进行对比分析。结果表明,经嵌筋加固后,墙体的破坏形式不同于普通墙体。高宽比为1.8的具有斜压破坏特征;高宽比为0.5的初裂时具有剪压破坏特征,极限荷载时具有剪压和剪摩擦破坏特征。
Embedded bars reinforcing is a new post-reinforced masonry wall reinforcement technique.According to the test results of the walls aspect ratio of 0.5 and 1.8,their failure modes and failure mechanism were analyzed.The results showed that reinforced by embedded bars,the failure mode of it is different from the ordinary one.The aspect ratio of 1.8 has the characteristics of baroclinic failure;when initial cracking happens,the aspect ratio of 0.5 has the characteristics of shear compression failure;when reaching the ultimate load,it has the characteristics of shear compression failure and shear friction failure.
引文
[1]施楚贤,周海兵.配筋砌体剪力墙的抗震性能[J].建筑结构学报,1997(6):32-40.
    [2]刘伟,刘立新,宫广娟.带翼缘短肢墙结构低周反复荷载试验研究[J].河南科学,2002,20(3):290-293.
    [3]费洪涛.配筋砌块短肢砌体剪力墙抗震性能的试验研究[D].哈尔滨:哈尔滨工业大学,2005.
    [4]罗青儿.配筋粉煤灰砌块砌体剪力墙的试验研究[D].南京:东南大学.2005.
    [5]翟希梅,唐岱新.带构造柱与带芯柱砌块墙体的抗震性能比较分析[J].建筑结构,2003(5):70-72.
    [6]丁世文.多孔砖、粉煤灰砌块、火山渣砌块配筋墙体抗震性能试验研究[J].地震工程与工程振动,2000,20(2):76-84.