基于MR-TMD的煤制气厂厂房半主动控制研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
提出了一种在TMD质量块上安装磁流变阻尼器的新型半主动MR-TMD控制装置,采用半主动控制算法,仿真分析了质量块在矩形波激励作用下,半主动MR-TMD控制系统对结构振动控制的可行性和有效性,并比较了半主动MR-TMD控制与被动TMD控制、主动AMD控制对同一模型结构的控制效果.仿真结果表明,半主动MR-TMD控制的减振性能优于被动的TMD控制和主动的AMD控制.
A new semi-active MR-TMD control device was proposed,which is installed on the TMD with a magneto-rheological damper.The feasibility and effectiveness of semi-active MR-TMD control system for structural vibration control under rectangular periodic excitations were simulated and analyzed by adopting one semi-active control algorithm proposed in the article.The control effect of semi-active MR-TMD,passive TMD and active AMD were compared by adopting the same model structure.Simulations numerical show that the damping performance of using semi-active MR-TMD control is better than that of using passive TMD control and active AMD control.
引文
[1]欧进萍.结构振动控制-主动、半主动和智能控制[M].北京:科学出版社,2003.
    [2]罗登贵,雷静雅,汲军广.房屋建筑基础设置磁流变阻尼器的半主动控制[J].武汉理工大学学报,2009,31(6):47-50.
    [3]秦丽,闫维明,呼学军,等.河南艺术中心标志塔TMD地震控制[J].北京工业大学学报,2009,35(6):761-768.
    [4]隋莉莉,欧进萍.MR减振驱动器用于结构振动控制的算法研究[J].应用力学学报,2002,19(3):144-148.
    [5]杨飏,欧进萍.多自由度结构的磁流变阻尼顶层隔振控制[J].世界地震工程,2008,24(2):85-89.