摘要
针对地震作用下砌体墙容易开裂、延性较差和混凝土墙刚度过大易导致薄弱层向上转移等问题,提出在房屋底层设置刚度可调、延性良好的新型抗侧力构件——密肋复合抗震墙,形成底部框架-密肋复合墙上部砌体结构,从框架-复合墙受力特点、框架与复合墙协同工作模型、复合墙有效刚度等方面对其抗震性能进行了详细分析,结合相关试验给出了底部框架密肋复合墙房屋结构实用抗震设计方法和构造措施.
In order to solve the problems under earthquake action as follows: the masonry wall is easy to crack and its ductility is bad,and rigidity oversized of concrete wall is easy to cause on the weak story to shift upwards,we propose to arrange a new type anti-lateral force component with adjustable rigidity and good ductility in the bottom layer.This paper analyzes its aseismic performance in detail,included stress characteristic of frame-composite wall,and the work model of frame cooperating with wall,and elastic equivalent stiffness and effective rigidity of multi-ribbed wall.Based on some related experiments,practical aseismic design method and detail measure of the structure are presented.
引文
[1]GB 50011-2001建筑结构抗震设计规范[S].北京:中国建筑工业出版社,2008.
    [2]GB 5003-2001砌体结构设计规范[S].北京:中国建筑工业出版社,2002.
    [3]孙景江,马强,石宏彬,等.汶川地震高烈度区城镇房屋震害简介[J].地震工程与工程振动,2008,28(3):8-15.
    [4]李翔,吕西林,李建中,等.汶川地震中广元市底层框架结构房屋震害调查与分析[J].结构工程师,2008,24(3):12-15.
    [5]崔鸿超.日本兵库县南部地震震害综述[J].建筑结构学报,1996,17(1):2-13.
    [6]郭猛,姚谦峰.框架-密肋复合墙结构新体系研究[J].地震工程与工程振动,2009,29(5):73-78.
    [7]Xia Lei,Yao Qianfeng,Chang Peng,et al.Seismicsafety evaluation analysis of a new building structurewith multi-ribbed composite wall structure[C]//Pro-ceedings of International Conference on EarthquakeEngineering:The First Anniversary of WenchuanEarthquake,2009:325-328.
    [8]Jia Yingjie,Yuan Quan,Yao Qianfeng.Research onShear Resistant Capacity and Reliability of Multi-rib-bed Composite Wall in High-rise Building[C]//Inter-national Symposium on Environmental Ecology andTechnology of Concrete,2005:669-675.
    [9]付秀黛,冯颖慧,叶建平.加十字形支撑的框架填充墙抗剪性能研究[J].河北建筑科技学院学报,2003,17(1):8-12.
    [10]河北省建设厅.DB13(J)64-2006密肋壁板结构技术规程[S],2006.