美国组合联肢剪力墙抗震设计方法探讨
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
基于美国加州建筑规范及其引用的相关设计规程和ASCE组合结构委员会的建议,介绍了由钢筋混凝土剪力墙与钢连梁组合而成的组合联肢剪力墙的抗震设计方法。该方法包括:基于中震的水平地震作用计算、合理耦连比的选择、中震及大震水平作用下钢连梁与剪力墙的抗震性能目标、基于先钢连梁屈服后剪力墙屈服的预定屈服机制的构件设计与验算等。据此,建议我国组合联肢剪力墙的第一阶段抗震设计应基于中震水平而不是小震水平。建议方法可供完善我国组合联肢剪力墙结构抗震设计参考。
In this paper,the seismic design method of the hybrid coupled wall structure in the United States is introduced based on the California Building Code and its referencing design standards and the Recommendations for Seismic Design of Hybrid Coupled Walls presented by the ASCE Committee on Composite Construction.The seismic design method described in this paper includes the earthquake action demand calculation,the seismic design performance levels,yielding mechanism design,the component design and check following the prescribed yield mechanism.It is suggested that the first stage seismic design of the hybrid wall be based on the design earthquake level instead of frequent earthquake level.This paper is helpful for developing a rational seismic design method for hybrid coupled walls in China.
引文
[1]吕西林,蒋欢军.复杂高层建筑抗震与消能减震进展[J].建筑结构学报,2010,31(6):52-61.(LUXilin,JIANG Huanjun.Research progress ofearthquake resistance and energy dissipation of complextall buildings[J].Journal of Building Structures,2010,31(6):52-61.(in Chinese))
    [2]王亚勇.汶川地震建筑震害启示:抗震概念设计[J].建筑结构学报,2008,29(4):20-25.(WANGYayong.Lessons learnt from building damages in theWenchuan earthquake:seismic concept design ofbuildings[J].Journal of Building Structures,2008,29(4):20-25.(in Chinese))
    [3]CBC 2007 California building code[S].Sacramento,California,USA:California Standards Commission,2007.
    [4]FEMA 450 NEHRP recommended provisions forseismic regulations for new buildings and otherstructures[S].Washington DC,USA:BuildingSeismic Safety Council,2003.
    [5]ASCE 7-05 Minimum design loads for buildings andother structures[S].Reston,VA,USA:AmericanSociety of Civil Engineers,2005.
    [6]AISC 341-05 Seismic provisions for structural steelbuildings[S].Chicago,Illinois,USA:AmericanInstitute of Steel Construction,2005.
    [7]ACI 318-08 Building code requirements for reinforcedconcrete and commentary[S].Farmington Hills,Michigan,USA:American Concrete Institute,2008.
    [8]EI-Tawil S,Harries K A,Fortmey P J,et al.Recommendations for seismic design of hybrid coupledwall systems[M].Reston,VA,USA:AmericanSociety of Civil Engineers,2010.
    [9]EI-Tawil S,Fortney P J,Harries K A,et al.Seismicdesign of hybrid coupled wall systems:state of the art[J].Journal of Structural Engineering,ASCE,2010,136(7):755-769.
    [10]Harries K A,McNeice D.Performance-based design ofhigh-rise coupled wall systems[J].The StructuralDesign of Tall and Special Structures,2006,15(3):289-306.
    [11]CSA A23.3-04 Design of concrete structures[S].Rexdale,Ontario,Canada:Canadian StandardsAssociation,2004.
    [12]Okazaki T,Engelhardt M D.Cyclic loading behavior ofEBF links constructed of ASTM A992 steel[J].Journalof Constructional Steel Research,2007,63(6):751-765.
    [13]Mattock A H,Gaafar G H.Strength of embedded steelsections as brackets[J].ACI Structural Journal,1982,79(2):83-93.
    [14]Becker R,Ishler M.Seismic design practice foreccentrically braced frames[M].Moraga,California,USA:Steel Tips,1996.