楼板隔震消能结构体系的参数优化
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
楼板隔震消能结构将部分楼板从主结构中分离出来,在楼板与梁之间设置高阻尼橡胶隔震支座,并在楼板与柱子之间的间隙设置消能阻尼器,从而形成一个大质量比的调谐质量阻尼器.文章对单层隔震楼板的参数优化问题进行了分析.结果表明:随着隔震楼板与主结构质量比的逐渐增大,隔震楼板与主结构最优频率比逐渐减小、最优阻尼比逐渐增大;主结构阻尼比越大,最优阻尼比越大、最优频率比越小.由于质量比较大,隔震楼板对减小主结构的响应非常有效.
In the floorslab isolating and energy dissipating(FIED) structural system,part of the floorslabs are isolated from the beams with high damping material and some dampers are set inside the gaps between the isolating floorslabs and the columns,so that a tuned mass damper with large mass ratio is actually formed.This paper has carried out the parameter optimization for the FIED structural system.It is found that with the increasing of the mass ratio of the isolating floorslab to the main structure,the optimum frequency ratio of the isolating floorslab to the main structure decreased and the optimum damping ratio of the isolating floorslab increased.The higher the damping ratio of the main structure,the lower the optimum frequency radio and the higher the optimum damping ratio.For having a large mass ratio,the FIED structural system is very effective in decreasing the seismic response of the main structure.
引文
[1]RANDA R,SOONG T T.Parametric study and simplified design of mass dampers[J].Engineering Structures,1998,20(3):193-204.
    [2]DEN HARTOG J P.Mechanical vibrations[M].4th ed.New York:McGraw-Hill,1956.
    [3]LUFT R W.Optimum tuned mass dampers for buildings[J].Structural Dynamics,ASCE,1979,105:2766-2772.
    [4]MCNAMARA R J.Tuned mass dampers for buildings[J].Structural Dynamics,ASCE,1977,103:1785-1798.
    [5]FAHIM S,BIJAN M.A method of estimating the parameters of tuned mass dampers for seismic applications[J].EarthquakeEngineering and Structural Dynamics,1977,26:617-635.
    [6]MAUTIZIO D A,SALVATORE P.Dynamic response and optimal design of structures with large mass ratio TMD[J].Earth-quake Engineering Structure Dynamical,2012,41:41-60.
    [7]FENG M Q,MITA A.Vibration control of tall building using mega subconfiguration[J].Journal of Engineering Mechanics,ASCE,1995,121:1082-1088.
    [8]VILLAVERDE R.Implementation study of aseismic roof isolation system in 13-story building[J].Journal of seismology andEarthquake Engineering,2000(2):17-27.
    [9]MATTA E,DESTEFANO A.Robust design of mass-uncertain rolling-pendulum TMDs for seismic protection of building[J].Mechanical Systems and Signal Processing,2009,23:127-147.
    [10]XIAN Qiao-ling,LIU Jian’an,ZHOU Fu-lin.Slab isolating and energy dissipating(SIED)structural system[J].Journal ofEarthquake Engineering and Engineering Vibration,2007,27(4):147-151.(in Chinese)
    [10]冼巧玲,刘建安,周福霖.楼板隔震消能结构体系[J].地震工程与工程振动,2007,27(4):147-151.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心