配筋率对混凝土剪力墙结构性能影响的试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
为使钢筋混凝土剪力墙在多层房屋中更合理的被使用,本文研究了八片分布筋配筋率在0.13%~0.23%之间的钢筋混凝土墙在低周反复加载下的受力性能。较系统的分析了其承载力、延性、刚度及其退化、耗能、破坏机制和破坏特性等。试验表明,该类配筋率墙体完全可以满足多层房屋结构抗震性能要求。
To find a more reasonable way for the use of reinforced concrete shear walls(RC-shear wall)in multi-story buildings,this paper researches the mechanical behavior of eight RC-shear walls with distributed reinforcement ratio between 0.13% and 0.23% under low-frequency quasi-static cyclic loading.Load-carrying capacity,stiffness and its degradation,ductility,hysteretic behavior,energy dissipation and failure phenomena of the shear walls are systematically analyzed.The results show that such walls with low reinforcement ratio are able to meet the requirements of seismic design for multi-storey building through rational design.
引文
[1]MARK FINTEL,Ductile Shear Walls in Earthquake ResistantMultistory Buildings[J].ACI Journal,June,1974,296~305.
    [2]JGJ3-2010,高层建筑混凝土结构技术规程[S].
    [3]GB50010-2010,混凝土结构设计规范[S].
    [4]魏金利.高层住宅钢筋混凝土结构设计问题探讨[J].工程建设与设计,2006,1:24~26.
    [5]朱伯龙.结构抗震试验[M].北京:地震出版社,1989.
    [6]方鄂华.多层及高层建筑结构设计[M].北京:地震出版社,1992.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心