对某12层的框架剪力墙结构工程实例进行了隔震设计计算分析。利用ETABS模型运用时程分析法对隔震结构进行了计算,由结果分析可知,隔震装置在多遇地震作用下能够延长结构的周期、减小结构的层间位移角,有效地减小结构的地震反应;在罕遇地震作用下楼层层间位移角能满足大震不倒的要求,隔震支座的位移和轴力均能满足现行抗震设计规范要求。
In this paper,a tall building project of seismic isolation design is calculated and analyzed.It is a frame-shear wall structure,which has twelve stories on the ground.And then,the time history analysis method is used to calculate the isolation structure.It is found that isolation equipment can extend the period of the structure and reduce the story drift in frequency earthquake.And it also can control the response of the structure.In rare earthquake,the story drift can meet the demand of uncollapse,the displacement and force of the equipment can satisfy the demand of the code for seismic design of building.
引文
[1]叶列平.土木工程科学前沿[M].北京:清华大学出版社,2006:139~169 Ye Lie-ping.Civil Engineering Frontiers of Science[M].Beijing:Tsinghua University Press,2006:139~169(in Chinese)
    [2]Farzad Naeim,James M Kelly.Design of Seismic Isolated Structures from Theory to Practice[M].John Wiley&Sons,Inc,1999
    [3]祝勤.隔震建筑隔震器的施工[J].浙江建筑,2000,97:24~25 Zhu Qin.Construction of Seismic Isolation Bearings in Building Structures[J].Zhejiang Construction,2000,97:24~25(in Chinese)
    [4]孟美莉,张德强.我国建筑物隔震与减震研究的现状与展望[J].河北建筑科技学院学报,2003,20(1):62~64 Meng Mei-li,Zhang De-qiang.Studies on Existing and Prospect of Shock Absorption and Shock Partition of Our Country[J].Journal of Heber Institute of Architectural Science and Technology,2003,20(1):62~64(in Chinese)
    [5]周福霖,谭平,温留汉,等.中国橡胶支座隔震与减震控制技术的研究与应用[A].2008全国橡胶工业信息发布暨减震橡胶技术研讨会论文[C],2008:112~126 Zhou Fu-lin,Tan Ping,Wen Liu-han et al.Reseach and Apply of Rubber Bearing of Isolation and Damping Control Technology in China[A].2008 National Rubber Industry Information Release and Damping Rubber Technology Seminar Thesis[C],2008:112~126(in Chinese)
    [6]卢丽娟,潘文,曾聪,等.昆明新机场航站楼隔震结构的地震反应分析[J].科学技术与工程,2010,10(15):3620~3624 Lu Li-juan,Pan Wen,Zeng Cong,et al.Seismic Responses Analysis of Isolator Structure of New Kunming Airport Terminal[J].Science Technology and Engieering,2010,10(15):3620~3624(in Chinese)
    [7]GB50011-2010,建筑抗震设计规范[S]GB50011-2010,Code for Seismic Design of Building[S](in Chinese)
    [8]王亚勇.建筑抗震设计规范(GB50011-2010)统一培训教材[M].北京:地震出版社,2010:57~61 Wang Ya-yong.Code for Seismic Design of Building(GB50011-2010)Unified Training Book[M].Beijing:Earthquake Publish Company,2010:57~61(in Chinese)