预制装配式剪力墙结构是实现住宅产业化及建筑节能减排的重要途径。从国家住宅产业化的发展、预制剪力墙整体及构件受力性能、带边框剪力墙的抗震性能、钢筋和钢管灌浆套筒连接技术、考虑加载速率影响的剪力墙抗震研究五个方面对剪力墙的受力性能、破坏机理、变形能力等方面进行综述。通过分析指出,将边框(钢管混凝土、型钢等约束端柱)引入预制装配式剪力墙中可以有效改善传统单一的抗震防线,利用约束端柱和剪力墙形成多道防线提高结构整体抗震性能。因此,对带边框预制装配式剪力墙的承载能力、变形性能、破坏模式等问题需要进行深入研究。
Prefabricated shear wall structure is the important way of realizing housing industry,energy saving and emission reduction.The research progress areas of precast shear wall mainly reflect five aspects:the development of national housing industry,the integral mechanical behavior of precast shear wall,seismic behavior of shear wall with frame column,the joint connection technique and seismic behavior of shear wall considering loading rate.On the basis of the above analysis,the frame column,such as steel tube concrete column,section steel,can be introduced into the precast shear wall.The new building structure can improve single seismic fortification line effectively depend on the frame column and shear wall,then carrying capacity,deformation performance and failure mode of prefabricated shear wall are worth studying further.
引文
[1]曾彬.钢管混凝土边框与剪力墙组合节点抗震性能试验研究[D].北京:北京工业大学,2009.
    [2]王翠坤,田春雨,肖从真.高层建筑中钢-混凝土组合结构的研究及应用进展[J].建筑结构,2011,41(11):28-33.
    [3]黄小坤,田春雨.预制装配式混凝土结构研究[J].住宅产业,2010,9:28-32.
    [4]张皓,李宏男.应变率对钢筋混凝土剪力墙动态性能的影响[J].防灾减灾工程学报,2010,30(3):303-308.
    [5]万科集团:2007年万科地产住宅产业化研究报告[R].2007.
    [6]张季超,楚先锋,邱剑辉,等.高效、节能、环保预制钢筋混凝土结构住宅体系及其产业化[J].工程力学,2008,25增刊:123-133,138.
    [7]姜阵剑.国内外住宅产业发展现状与发展方向[J].建筑,2004,5:81-83.
    [8]陈彤,郭惠琴,马涛,等.装配整体式剪力墙结构在住宅产业化试点工程中应用[J].建筑结构,2011,41(2):26-30.
    [9]朱张峰,郭正兴.预制装配式剪力墙结构墙板节点抗震性能研究[J].地震工程与工程振动,2011,31(1):35-40.
    [10]陆建忠,郭正兴,董年才.全预制装配整体式剪力墙结构抗震性能研究[J].施工技术,2011,40(342):16-19.
    [11]钱稼茹,彭媛媛,张景明,等.竖向钢筋套筒浆锚连接的预制剪力墙抗震性能试验[J].建筑结构,2011,41(2):1-6.
    [12]钱稼茹,彭媛媛,秦珩,等.竖向钢筋留洞浆锚间接搭接的预制剪力墙抗震性能试验[J].建筑结构,2011,41(2):7-11.
    [13]张微敬,钱稼茹,陈康,等.竖向分布钢筋单排连接的预制剪力墙抗震性能试验[J].建筑结构,2011,41(2):12-16.
    [14]陈再现,姜洪斌,张家齐,等.预制钢筋混凝土剪力墙结构拟动力子结构试验研究[J].建筑结构学报,2011,32(6):41-50.
    [15]姜洪斌,陈再现,张家齐,等.预制钢筋混凝土剪力墙结构拟静力试验研究[J].建筑结构学报,2011,32(6):34-40.
    [16]郭正兴,董年才,朱张峰.全预制装配整体式剪力墙结构墙板节点抗震性能仿真分析[J].施工技术,2011,40(342):20-22.
    [17]Arturo E.Schultz.Seismic resistance of vertical joints in precast shear walls[C].Federation international de la precontrainte,Proceedings of the12th congress,vol.1,23-27,1994.
    [18]J.C.Adajar,T.Yamaguchi.New connections method for precast shear walls[C].Eleventh world conference on earthquake engineering,papernumber 590,1996.
    [19]A.E.Schultz,B.Erkmen,R.A.Magana.Seismic design factors for precast concrete shear wall parking garages[C].13th world conference onearthquake engineering,paper number 2076,2004.
    [20]廖飞宇,陶忠,韩林海.钢-混凝土组合剪力墙抗震性能研究简述[J].地震工程与工程振动,2006,26(5):129-135.
    [21]罗英,赵世春.带SRC边框低剪力墙的抗震性能试验研究[J].西安公路交通大学学报,1999,19(2):66-69.
    [22]钱稼茹,江枣,纪晓东.高轴压比钢管混凝土剪力墙抗震性能试验研究[J].建筑结构学报,2010,31(1):40-48.
    [23]曹万林,王敏,张建伟,等.钢管混凝土边框剪力墙抗震试验及承载力计算[J].北京工业大学学报,2008,34(12):1291-1297.
    [24]Driver Robert G,Kulak Geoffrey L,Kenned D J Laurie,et al.Cyclic test of four story steel plate shear wall[J].Journal of Structural Engineering,1998,124(2):112-120.
    [25]夏汉强,刘嘉祥.矩形钢管混凝土柱带框剪力墙的应用及受力分析[J].建筑结构,2005,35(1):16-18.
    [26]廖飞宇,陶忠,韩林海.带钢管混凝土边框柱的RC剪力墙力学性能分析[J].第17届全国结构工程学术会议论文集(第Ⅰ册),2008,370-373.
    [27]成锟,张延庆.方钢管混凝土约束端柱组合剪力墙非线性有限元分析[J].建筑技术开发,2009,36(9):3-5,11.
    [28]曹万林,王敏,王绍合,等.高轴压比下钢管混凝土边框组合剪力墙抗震性能试验研究[J].地震工程与工程振动,2008,28(1):85-90.
    [29]王敏,曹万林,张建伟,等.钢管混凝土边框高强混凝土组合剪力墙抗震性能试验研究[J].地震工程与工程振动,2008,28(2):90-95.
    [30]曹万林,曾彬,王敏,等.钢管混凝土边框与剪力墙连接键工作性能试验[J].北京工业大学学报,2009,35(5):603-610.
    [31]杨亚彬,张建伟,曹万林,等.圆钢管混凝土边框剪力墙抗震性能试验研究[J].北京工业大学学报,2011,27(3):78-82.
    [32]张建伟,杨亚彬,曹万林,等.圆钢管混凝土边框多重组合低矮剪力墙的抗震性能[J].建筑科学与工程学报,2011,28(3):23-28,33.
    [33]曹万林,杨亚彬,张建伟,等.圆钢管混凝土边框内藏桁架剪力墙抗震性能[J].东南大学学报(自然科学版),2009,36(6):1187-1192.
    [34]中国工程建设标准化协会标准,矩形钢管混凝土结构技术规程(CECS159:2004)[S].北京:中国计划出版社,2004.
    [35]中国工程建设标准化协会标准,钢管混凝土结构设计与施工规程(CECS28:90)[S].1990.
    [36]韩林海.钢管混凝土结构:理论与实践[M],北京:科学出版社,2004.
    [37]韩瑞龙,施卫星,周洋.灌浆套筒连接技术及其应用[J].结构工程师,2011,27(3):149-153.
    [38]张莉若,汤中发,王明贵.套筒式钢管混凝土梁柱节点试验研究[J].建筑结构,2005,35(8):73-75,84.
    [39]钱稼茹,彭媛媛,张景明,等.竖向钢筋套筒浆锚连接的预制剪力墙抗震性能试验[J].建筑结构,2011,41(2):1-6.
    [40]姜洪斌,张海顺,刘文清,等.预制混凝土插入式预留孔灌浆钢筋搭接试验[J].哈尔滨工业大学学报,2011,43(10):18-23.
    [41]王爱军.钢筋灌浆直螺纹连接技术及应用[J].建筑机械化,2010,增刊:21-25.
    [42]Xiao-Ling Zhao,Paul Grundy and Yee-Teck Lee.Grout sleeve connections under large deformation cyclic loading[C].Proceedings of the twelfthinternational offshore and polar engineering conference,Japan,2002:54-59.
    [43]赵媛媛,蒋首超.灌浆套管节点技术研究概况[J].工业建筑,2010,39:514-517.
    [44]陈俊名.钢筋混凝土剪力墙动力加载试验及考虑应变率效应的有限元模拟[D].湖南大学,2010.
    [45]Kazushi Shimazaki,Akira Wada.Dynamic analysis of a reinforced concrete shear wall with strain rate effect[J].ACI Structural Journal,1998,95(5):488-497.
    [46]Fumiya Esaki,Masayuki Ono.Effect of loading rate on mechanical behavior of SRC shear walls[J].Steel and Composite Structures,2001,1(2):201-212.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心