某水电站厂房进水塔静动力安全分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
采用三维有限元法计算了某水电站厂房进水塔地震作用下的动力响应,对静动力下塔体的位移和应力进行安全验算,对基础面法向力进行了强度校核。计算结果表明,进水塔结构设计合理,整体安全。
The dynamic responses of powerhouse intake tower of a hydropower station under earthquake action are calculated based on 3D finite element method,and check computation are carried out to safe displacement and stress under combinations of static and dynamic forces.Besides,normal stress strength in foundation base is also checked.The calculation results showthat the design ofintake tower is reasonable and safe.
引文
[1]GB18306-2001,中国地震动峰值加速度区划图[S].
    [2]DL5073-2000,水工建筑物抗震设计规范[S].
    [3]DL5077-1997,水工建筑物荷载设计规范[S].
    [4]DL/T5057-1996,水工混凝土结构设计规范[S].
    [5]SL266-2001,水电站厂房设计规范[S].

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心