地铁车站结构抗震分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
结合厦门地铁吕厝站工程实例,根据时程分析法的基本原理,应用有限元建模软件Midas进行有限元建模、计算,经抗震分析可知在地震组合工况作用下,主体地下结构的相对水平位移峰值均较小,全部构件的实际配筋均满足抗震分析要求。
Combining with the Lvcuo Station of Xiamen Subway example,the paper applies the finite element modeling software,Midas,to undertake the finite element modeling and calculation according to the basic principle of the time-histories analysis,and proves by the anti-seismic analysis that the relatively horizontal peak displacement of the main underground structure is relatively small and the factual reinforcement of all the components can meet the requirement of the anti-seismic analysis under the seismic combination situation.
引文
[1]田雪娟.地铁车站抗震分析[J].铁道建筑技术,2012(6):67-73.
    [2]任强.基于ANSYS的某明挖地铁车站抗震分析[J].现代商贸工业,2010,22(11):334-335.
    [3]徐宏,卢登榜,俞晓亮,等.南京地铁双层车站抗震分析[J].江苏建筑,2008(1):26-28.
    [4]GB50009-2001,建筑结构荷载规范[S].
    [5]GB50011-2010,建筑抗震设计规范[S].
    [6]GB50010-2010,混凝土结构设计规范[S].
    [7]李建亮,赵晶,李福海,等.隧道结构抗震设计时程分析法的分析研究[J].四川地震,2011(4):25-28.
    [8]尤宇星,黄圣棕,谢文杰.建筑结构时程分析法中天然地震波的选择[J].地震地磁观测与研究,2011,32(4):22-26.
    [9]王西宁.论述建筑结构抗震设计方法[J].黑龙江科技信息,2010(23):239-241.