通过建立超大型冷却塔三维有限元模型,在考虑土-结构相互作用情况下,对超大型冷却塔结构进行动力特性分析,并与刚性地基的结果进行对比。用反应谱分析计算了单向地震的作用和效应,并采用双向地震与自重、风荷栽、温度荷载工况进行了组合,得到了相应工况的内力和位移,为工程设计提供了参考。
A three-dimensional finite element model was built for super large cooling tower.Comparing with the results of rigid foundation,the analysis of dynamic characteristics was carried considering soilstructure interaction.Effect and response under unidirectional earthquake action were calculated by response spectrum analysis.Furthermore considering bilateral seismic conbined with dead weight,wind load,and temperature load condition,the internal force and displacement of corresponding condition were also obtained, they would provide reference for engineering designing.
引文
[1]沈聚敏,周锡元等.抗震工程学[M].北京:中国建设工业出版社,2000
    [2]Wolf,J.P.Dynamic Soil-Structure Interaction[M].Prentice-Hall.Inc. Englewood Cliffs,N.J.1985
    [3]R.克拉夫,J.彭津,王光远等译.结构动力学[M].北京:高等教育出版社,2006.11
    [4]孔麟.超大型间接空冷塔的地震反应分析[D].西安:西安理工大学,2009
    [5]火力发电厂水工设计规范DL/T 5339-2006(中华人民共和国电力行业标准).中国电力出版社,2006:112-113
    [6]王社良,抗震结构设计[M].武汉:武汉理工大学出版社, 2007.12
    [7]张俊发,黄瑜,闻建军.群桩基础的复合体模型建立与应用[J].岩土工程学报,2006.9,28(9):64-69
    [8]李静,陈健云.动力相互作用分析中无质量地基的应用研究[J].世界地震工程,2007,23(2):58-62
    [9]构筑物抗震设计规范GB 50191-93(中华人民共和国国家标准).中国计划出版社,1994:24-26
    [10]K.R.Dhawan,D.N.Singh,I.D.Gupta.Three-Dimensional Finite Element Analysis of Under-ground Cavems[J].International Journal of Geomechanics.2004,4(3):224-228