核级手动偏心球阀抗震分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
利用ANSYS软件建立了手动偏心球阀的三维有限元模型,进行抗震分析,不仅进行了静力分析,还选取常见的典型地震波进行谱分析和时程分析。通过计算比较,发现三种方法应力计算结果接近;在计算效率上,静力分析优于谱分析和时程分析。
In this study,the three-dimensional finite element model of manual eccentric ball valve is built using ANSYS software. Then the seismic analysis is carried out. Not only the static analysis is carried out,but also the spectrum analysis and time-history analysis are carried out through selecting common typical earthquake wave. Through comparison,we find the three results are close,but the static method is conservative. According to the actual requirements,the calculation results are close among three methods. In the computation efficiency,the static analysis is better than the spectrum analysis and time-history analysis.
引文
[1]刘志香.球阀的动态特性与应用[D].济南:山东大学,2007.
    [2]翟欢乐,余于仿,张为,等.核级阀门电动执行机构抗震分析与试验[J].机电工程技术,2012(7):171-174.
    [3]贾臻,王会,龚自力.核级球阀的力学分析[C].中国核学会2011年学术年会论文集第3册,2011:715-719.
    [4]王伟.核安全二级气动启动球阀力学分析[J].核动力工程,2012,33(2):47-23.
    [5]蔡坤,乐修辉,等.核安全二级阀门抗震分析方法[J].阀门,2012(3):28-30.
    [6]周文霞,张继革,宋志平,等.核2级调节阀的抗震分析及试验研究[J].世界地震工程,2011,27(1):148-152.
    [7]EJ/T 1022.14-96.压水堆核电厂阀门应力分析和抗震分析[S].
    [8]刘爱国,陆道纲,温家良,等.直流换向阀抗震分析技术的研究[J].振动与冲击,2011,30(2):226-232.
    [9]RCC-M 2000+2002补遗:压水堆核岛机械设备设计和建造规则[Z].法国核岛设备设计制造规则协会.
    [10]张洪才,何波.有限元分析—ANSYS 13.0从入门到实战[M].北京:机械工业出版社,2012.
    [11]刘龙,迮晓锋,于新海,等.核安全级安全阀抗震应力分析与评定[J].阀门,2009(6):29-31.
    [12]蒋甫玉,高丽坤.基于余弦变换的地震动反应谱计算方法[J].工程力学,2011,28(2):49-56.
    [13]GB500ll-2001.建筑抗震设计规范[S].
    [14]朱新华,黎小林,肖晋,等.有限元分析在特高压换流阀抗震设计中的应用[J].南方电网技术,2009,3(6):91-94.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心