故宫灵沼轩钢结构抗震性能分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
基于钢结点的半刚性特征及退化现状,建立结构有限元模型。通过模态分析,研究结构基频和主振型;通过谱分析,研究Ⅷ度常遇地震作用下钢结构的内力及变形分布特征;通过时程分析,研究Ⅷ度罕遇地震作用下钢结构的抗倒塌能力。结果表明:灵沼轩钢结构基频为5.31Hz,主振型以钢框架顶部的八角亭水平向弯曲为主。Ⅷ度常遇地震作用下,由于钢框架2层顶部结点刚度退化严重,其变形和内力普遍较大,但满足容许值要求。Ⅷ度罕遇地震作用下,钢结构薄弱层的变形峰值在容许范围内,结构不会产生倒塌。
Lingzhao Veranda(also called Crystal Palace)is located in the eastern part of the Palace Museum(the Forbidden City),which was planned for the amusement of the royal family in20 th century.However,construction of the building lasted only three years,and the building has lain idle until the present.The building is composed of a center bearing frame and four surrounding white marble verandas.The frame is composed of I-section steel beams and a ring of iron columns.In addition,on top of the bearing frame and verandas,there are five iron booths.Because the building has been idle for nearly 100 years,structural problems have appeared on the frame due to a number of factors,such as shortage of bolts,slack in joint connections,and cracks in the iron columns.The National Center for Quality Supervision and Testing of Building Engineering has conducted on-site inspections of the steel structure,and concluded that the beams and columns are structurally sound.However,the joints need to be strengthened.As a historic building,the Lingzhao Veranda is worth protection for its artistic,historical,cultural,and architectural values.To effectively protect this historic building,it is necessary to assess its current structural safety.Such an assessment may provide a direction for future maintenance and restoration of the building.The status of the structure can be determined through simulation methods.For the purpose of this study,the ANSYS program was used to study the aseismic performance of the steel structure.Beams and columns of the frame are connected by steel bolts,which form a type of semi-rigid joint to release part of moment of the joint.Three spring elements of the ANSYS program are used to simulate rotation stiffness values of the beam-column joints.The degradation of rotation stiffness in the joints is also considered.In addition,because some steel beams are embedded in the white marble walls,the embedded locations of the beams are considered as a fixed boundary.Accordingly,the finite element model of the steel structure is developed.Using modal analysis,the structure's basic frequencies and primary modes are determined.Using response spectrum analysis,the distribution of its deformation as well as internal forces underⅧ-degree intensity of frequently occurred earthquakes are analyzed.Using time history analysis,the structure's anticollapse performance underⅧ-degree intensity of rare earthquake events is estimated.Results of modal analysis show that the basic frequency of the steel structure is 5.31 Hz.The structure's primary modes focus on mode 5in xdirection and mode 1in ydirection.Both modes behave as a local vibration of the steel booths in level directions,which relates closely to degradation of the stiffness in its beam-column joints.The response spectrum analysis shows that,under Ⅷ-degree intensity of frequently occurred earthquakes,values for deformation as well as stress in the steel structure are within permissible ranges.This is attributable to many factors,including several beams embedded into walls that serve as additional supports for the center frame,and the high strength of the steel(iron)material.In addition,the locations of the peak deformation and stress are near the top of the columns,reflecting the ease with which the slack in the joints can easily cause lateral deformation or failure of the columns.The results of time history analysis show that,under the Ⅷ-degree intensity of rare occurred earthquakes,displacement response curves of the typical nodes in the steel structure reflect a nearly even fluctuation based on balance locations.In turn,this means that the steel structure maintains a stable vibration status.Because the peak deformation value of the weak layer of the structure is still within permissible ranges,the structure is not expected to collapse.
引文
[1]故宫灵沼轩钢结构检测鉴定报告[R].北京:国家建筑工程质量监督检验中心,2011.Inspection Report of Steel Structures of LING-Zhao Veranda in the Forbidden City[R].Beijing:National Center for Quality Supervision and Test of Building Engineering,2011.(in Chinese)
    [2]陈宏,施龙杰,王元清,等.钢结构半刚性结点的数值模拟与试验分析[J].中国矿业大学学报,2005,34(1):102-106.CHEN Hong,SHI Long-jie,WANG Yuan-qing,et al.Numerical Simulation and Experimental Analysis on Steel Semi-rigid Joints[J].Journal of China University of Mining&Technology,2005,34(1):102-106.(in Chinese)
    [3]黄冀卓,王湛,潘建荣.钢结构梁柱连接结点刚度的半解析测试方法[J].工程力学,2011,28(1):105-109.HUANG Ji-zhuo,WANG Zhan,PAN Jian-rong.Semi-analytical Method for Beam-to-column Connection Rigidity of Steel Structures[J].Engineering Mechanics,2011,28(1):105-109.(in Chinese)
    [4]杜俊,印真,陈力奋.梁柱半刚性连接对钢结构整体抗震性能的影响研究[J].动力学与控制学报,2013,11(2):172-177.DU Jun,YIN Zhen,CHEN Li-fen.The Effects of Semi-rigid Joints on the Seismic Behaviors of Steel Structure[J].Journal of Dynamics and Control,2013,11(2):172-177.(in Chinese)
    [5]Atorod A,James B R.Static and Cyclic Performance of Semi Rigid Steel Beam to Column Connections[J].Journal of Structural Engineering,1989,115(12):2979-2999.
    [6]Hong K,YANG J G,Lee S K.Parametric Study of Double Angle Framing Connections Subjected to Shear and Tension[J].Journal of Constructional Steel Research,2001,57:997-1013.
    [7]李春锋,杜永峰,李慧.阻尼连体结构地震响应影响参数研究[J].西北地震学报,2012,34(1):33-38.LI Chun-feng,DU Yong-feng,LI Hui.Study of Seismic Response Influence Parameters on Damping Connective Structure[J].Northwestern Seismological Journal,2012,34(1):33-38.(in Chinese)
    [8]杜永峰,张尚荣,李慧.多级串联非比例阻尼隔震结构地震响应分析[J].西北地震学报,2012,34(4):319-323.DU Yong-feng,ZHANG Shang-rong,LI Hui.Seismic Response Analysis on Multistage Series Non-proportion Damping Isolated Structure[J].Northwestern Seismological Journal,2012,34(4):319-323.(in Chinese)
    [9]李慧,包超,杜永峰.近场地震作用下不规则层间隔震结构的动力响应分析[J].地震工程学报,2013,35(1):51-55.LI Hui,BAO Chao,DU Yong-feng.Dynamic Response Analysis of Irregular Story Isolation Structures Under Near-field Earthquake Conditions[J].China Earthquake Engineering Journal,2013,35(1):51-55.(in Chinese)
    [10]Fang D P,Lwasaki S,YU M H.Ancient Chinese Timber Architecture-I:Experimental Study[J].Journal of Structural Engineering,2001,127(11):1348-1357.
    [11]Fang D P,Iwasaki S,YU M H.Ancient Chinese Timber Architecture-II:Dynamic Characteristics[J].Journal of Structural Engineering.2001,127(11):1358-1364.
    [12]石永久,施刚,王元清.钢结构半刚性端板连接弯矩-转角曲线简化计算方法[J].土木工程学报,2006,39(3):19-23.SHI Yong-jiu,Shi Gang,WANG Yuan-qing.a Simplified Calculation Method for Moment-rotation Curve of Semi-rigid End-plate Connections[J].China Civil Engineering Journal,2006,39(3):19-23.(in Chinese)
    [13]李国强,王静峰,刘清平.竖向荷载下足尺半刚性连接组合框架试验研究[J].土木工程学报,2006,39(7):43-51.LI Guo-qiang,WANG Jing-feng,LIU Qing-ping.An Experimental Study of Full-scale Semi-rigid Composite Frames Under Vertical Loading[J].China Civil Engineering Journal,2006,39(7):43-51.(in Chinese)
    [14]中华人民共和国住房和城乡建设部.GB 50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.Ministry of Housing and Urban-Rural Development of the People’s Republic of China.GB 50011-2010Code for Seismic Design of Buildings[S].Beijing:China Architecture&Building Press,2010.(in Chinese)
    [15]中华人民共和国建设部.GB 50017-2003钢结构设计规范[S].北京:中国计划出版社,2003.Ministry of Construction of the People’s Republic of China.GB 50017-2003Code for Design of Steel Structures[S].Beijing:China Jihua Press,2003.(in Chinese)

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心