基于火灾实验的板房和帐篷防火间距确定
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
在聚苯乙烯彩钢夹芯板房和标准救灾帐篷全尺寸火灾实验的基础上,模拟板房和帐篷防火间距,模拟结果与实验结果吻合良好。通过回归整理分别建立了板房和帐篷防火间距的数学模型,建议帐篷组团内行距不应小于4m,组团之间宜保持12m以上的防火间距。
Based on the full-scale fire test of prefabricated house made of polystyrene color steel and the standard relief tent,the fire separation distance between prefabricated houses or relief tents were simulated,and the simulation results fits the experiment results well.By regression,the mathematical expressions of fire separation distance between color steel houses or relief tents were produced.It was suggested that the distance should be no less than 4minside the tent group,and over 12mbetween each tent group.
引文
[1]四川省消防总队.板房火灾实验研究报告[S].2010.
    [2]宋晓勇.彩钢夹芯板房和帐篷的防火间距研究[J].消防科学与技术,2011,30(11):1007-1010.