汽轮发电机基础抗震性能拟动力试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
本文以1251MW汽轮发电机基础为研究对象,设计制作了1:8的试验模型,进行了7度多遇地震与罕遇地震作用下的拟动力试验,研究了基础的地震反应特性。试验结果表明,该基础具有较好的抗震安全储备,即使将设计基准期由50年调整到60年,基础仍能满足抗震设计标准要求。
In this paper,taking a 1251MW steam-turbine generator foundation as an example,pseudo-dynamic tests under intensity 7 frequently and rarely earthquake are carried out after designing and building a 1∶8 scale testing model.And the characteristics of earthquake response are studied.The results indicate that the foundation has preferable seismic capability during the earthquake.Even the design reference period is adjusted from 50 years to 60 years,the foundation meets seismic design codes requirements.
引文
[1]王宝齐,马华,周锡元,代泽兵.大型汽轮发电机基础结构抗震性能试验研究[J].电力建设,2008,29(8):13~17 Wang Bao-qi,Ma Hua,Zhou Xi-yuan,Dai Ze-bing.Experimental Study on Large Turbine Generator Foundation Anti-seismic Performance[J].Electric Power Construction,2008,29(8):13~17(in Chinese)
    [2]黄怡萍.不同设计基准期建筑的设计地震作用取值的计算[J].科技创新导报,2011,(29):41
    [3]GB50011-2010,建筑抗震设计规范[S]GB50011-2010,Code for Seismic Design of Buildings[S](in Chinese)
    [4]胡聿贤.地震工程学(第二版)[M].北京:地震出版社,2005 Hu Yu-xian.Earthquake Engineering[M].Beijing:Seismological Press,2005(in Chinese)
    [5]朱祝兵,屈铁军.大型汽机基础地震输入研究[J].北方工业大学学报,2009,21(1):81~84 Zhu Zhu-bing,Qu Tie-jun.Seismic Input Research on Large Steam-turbine Generator Foundation[J].Journal of North China University of Technology,2009,21(1):81~84(in Chinese)
    [6]屈铁军,朱祝兵.软土地基汽轮发电机基础抗震性能实验[J].防灾减灾工程学报,2007,27(增刊):200~204Qu Tie-jun,Zhu Zhu-bing.Experiment Study of the Anti-scismic Performance of Turbine Generator Foundation on Soft Soil[J].Journal of Disaster Prevention and Mitigation Engineering,2007,27(Sup.):200~204.
    [7]严乐,田树桐,王佩,等.600MW汽轮发电机基础抗震试验研究[J].武汉大学学报(工学版),2010,8(增刊):156~159 Yan Le,Tian Shu-tong,Wang Pei,et al.Aseismic Test Study of Foundations of600MW Steam Turbo-Generator[J].Engineering Journal of Wuhan University,2010,8(supplement):156~159(in Chinese)

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心