地下结构横断面地震反应简化计算方法探讨
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
针对矩形断面地下结构断面内地震变形及内力分析的相互作用系数法进行研究。首先分析了柔度比、结构埋深及尺寸等对土-地下结构相互作用系数的影响,提出在考虑这些因素影响的情况下相互作用系数的计算方法;进而针对目前文献中多考虑地下结构变形的计算,对相应内力的计算研究较少的情况,提出了一种加载方法。利用该方法,可由已计算的结构变形算出较准确的结构内力;最后,对所提出的加载方法的主要影响因素进行了分析。
Based on the soil-structure interaction coefficient method,the sectional seismic response of underground structures with rectangular cross section is investigated.Firstly the factors influencing the soil-structure interaction coefficient,including the flexibility ratio,the burial depth and the structural dimensions are analyzed.Noting the situation that calculation methods in many literatures can only give the shear deformation of the structures but have not enough consideration of internal force calculation,a simplified loading method is proposed to get the internal force with the already calculated deformation of the structures.Also,some important factors influencing the results of the loading method are analyzed.
引文
[1]GB50157-2003.地下铁道设计规范[S].北京:中国计划出版社,2003.(GB50157-2003.Code for theDesign of Subways[S].Beijing:China Planning Press,2003.(in Chinese))
    [2]周健,苏燕,董鹏.软土地层地铁及地下构筑物抗震动力分析研究现状[J].地下空间,2003,23(2):173-178.(ZHOU Jian,SU Yan,DONG Peng.State ofthe art of seismic analysis of subway and undergroundstructures in soft soil[J].Underground Space,2003,23(2):173-178.(in Chinese))
    [3]施仲衡.地下铁道设计与施工[M].西安:陕西科学技术出版社,1997.(SHI Zhong-heng.Subway Designand Construction.Xi’an:Shanxi Science and Technol-ogy Press,1997.(in Chinese))
    [4]Jaw-Nan(Joe)Wang.Seismic Design of tunnels:Asimple state-of-the-art design approach,Monograph7[M].Parsons Brinckerhoff Quade and Douglas Inc,New York,1993.
    [5]李子豪.地铁地下结构横截面震动变形的实用评价方法[D].北京:清华大学,2006.(LI Zi-hao.Practi-cal methods for evaluating sectional seismic deformationof subway structures[D].Beijing:Tsinghua Universi-ty,2006.(in Chinese))