高层钢-混凝土组合门式结构消能减震体系模拟地震振动台试验研究
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
对一幢复杂高层钢-混凝土组合门式结构消能减震体系的1/30缩尺模型进行了模拟地震振动台试验,深入研究了该结构的动力特性和地震反应特征,通过比较验证了粘滞阻尼器的减震效果。结果表明:结构整体空间作用显著,两座塔楼之间扭转反应较大。有、无阻尼器结构的各项反应基本满足抗震规范的要求;从平均意义上讲,阻尼器对整体结构的位移反应有一定的控制效果,对结构高空连廊的位移和两座塔楼之间的扭转反应控制效果较好。
In the paper,a 1/30 scale model of high-rise portal-shaped steel-concrete hybird building with viscous dampers was tested on shaking table to study the dynamic characteristics,seismic responses and the effect of dampers on seismic behaviors of the structure.Test results show that the torsion responses between tower 1 and tower 2 is obvious,yet the seismic response of the whole structure meets the code requirement.The dampers play an important role in energy dissipation,and the displacement of the high-altitude gallery and the torsion response of the two towers are greatly reduced.
引文
[1]陈永祁,杜义欣.液体粘滞阻尼器在结构工程中的最新进展[J].工程抗震与加固改造,2006,28(3):65-72.
    [2]沈朝勇,周福霖,等.带连廊-复杂体型高层结构模型试验研究[J].广州大学学报,2004,3(2):143-149.
    [3]周颖,吕西林,卢文胜,等.双塔连体高层混合结构抗震性能研究[J].地震工程与工程振动,2008,28(5):71-78.
    [4]黄襄云,刁云云,谭平,等.多塔楼高层建筑连廊结构的柔性连接设计及试验研究[J].地震工程与工程振动,2007,27(6):112-118.
    [5]孟春光,丁洁民,吕西林,等.带阻尼器高层方钢管混凝土框架结构模拟地震振动台试验研究[J].结构工程师,2005,21(5):57-62.
    [6]王翠坤,赵鹏飞,马宏睿,等.深圳大梅沙酒店模型振动台试验及减震阻尼器设计研究[J].建筑结构,2006,(36)增刊:8-12.
    [7]吕西林,周强.铅芯橡胶耗能器与油阻尼器组合耗能系统的振动台试验与分析[J].力学季刊,2001,22(1):117-127.
    [8]韩强,杜修力,刘晶波,等.多维地震作用下隔震桥梁地震反应(Ⅰ)—模型结构振动台试验[J].振动与冲击,2008,27(9):59-65.
    [9]樊珂.大跨度结构多维多点地震响应试验研究与理论分析[D].北京:北京工业大学,2008.
    [10]建筑抗震设计规范(GB 50011-2001).北京:中国建筑工业出版社,2001.
    [11]吕西林著.复杂高层建筑结构抗震理论与应用[M].北京:科学出版社,2007,201-219.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心