地震次生火灾扑救力量评估及优化
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
介绍城市消防车辆布局评估方法和优化配置方法。评估沈阳市消防车辆布局,认为常态下,沈阳市消防车辆布局合理。在计算分析震后灭火扑救行动时间的基础上提出避免救援出动延迟的消防车辆优化布局配置方案。通过消防资源优化配置方案,沈阳市评级为合理或基本合理的被保护建筑比例为81.2%,在地震次生火灾处置中,沈阳市消防车辆装备布局趋近合理。
The assessment and optimization of city fire engines arrangement are introduced.The fire engines arrangement in Shenyang is evaluated,and is rated to be reasonable in generalsituation.Based on the calculation of acting time in post-earthquake fire fighting,the optimization of fire engine arrangement is put forward to avoid delay of rescuing action.After the optimization,proportion of building protection in Shenyang rated reasonable and primary reasonable is 82.1%,which means the fire engines arrangement in Shenyang is proper to deal with the post-earthquake fire.
引文
[1]赵荣国,李卫平.浅析现代城市地震火灾和减灾问题[J].城市防震减灾,1999,2(2):14-17.
    [2]李树,吕昭河,唐朝纲,等.城市化进程对火灾的影响关系分析[J].消防科学与技术,2006,25(3):396-398.
    [3]胡传平.区域火灾风险评估与区域灭火救援力量布局优化研究[D].上海:同济大学,2006.
    [4]陈艳艳,郭国旗.城市消防站的优化布局[J].消防科学与技术,1999,18(1):26-28.
    [5]韩阳.城市地下管网系统的地震可靠性研究[D].大连:大连理工大学,2002.
    [6]吴军.基于风险的灭火救援力量优化布局[J].消防科学与技术,2004,23(2):179-181.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心