摘要
结构在罕遇地震作用下会进入弹塑性并产生损伤,准确预测地震荷载下结构的非线性行为,对评估结构的抗震安全性具有重要意义。某框架结构采用非线性粘滞流体阻尼器对现有结构进行抗震加固。文章采用纤维模型直接将构件的非线性节点力、节点变形和材料的非线性应力-应变行为联系起来,准确模拟地震作用下结构的三维非线性地震响应。利用纤维模型对该工程结构进行了动力弹塑性时程分析,结果表明采用阻尼器对结构进行消能减震设计后,能够延缓结构的塑性行为发展程度,满足设计目标。
Structures will enter nonlinear stage during strong earthquakes.Hence accurate prediction for the structural nonlinear behaviors is important to the safety and loss assessment during earthquakes.Nonlinear fluid dampers are installed in a frame structure to reinforce it.This paper adopts fiber model which connect the material stress-strain relationship directly with the force-displacement behavior of the structural elements to simulated the spatial seismic responds of structures precisely.The structure is analyzed with dynamic time-history analysis to show that the dampers can delay the development degree of plastic behavior,meet design targets.
引文
[1]俞剑锋,张志强.基于性能的框架结构消能减震设计方法在加固工程中的应用[C]//第二届结构工程新进展国际论坛.南京:2010.
    [2]李爱群.工程结构减振控制[M].机械工业出版社,2007:239-241.
    [3]PERFORM-3D User Guide[M].CSI,2006.
    [4]PERFORM-3D Components and Elements[M]:CSI.2006.
    [5]缪志伟,等.某框架偏心核心筒弹塑性分析[J].四川建筑科学研究,.2008,34(3):5-10.
    [6]GB50010-2010混凝土结构设计规范[S].北京:中国建筑工业出版社,2010.
    [7]GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.