核电低压缸及凝汽器的地震响应分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
以建筑抗震设计规范标准为依据,采用有限元法对某核电低压缸及凝汽器结构的地震响应进行了分析,通过地震时程分析法和反应谱分析法得到低压缸及凝汽器在水平和竖向方向地震荷载作用下的位移响应特征.结果表明,该低压缸及凝汽器结构的地震响应呈现出板结构的振型特征,其抗震性能优于一般的建筑结构.
A series of finite element method(FEM) analysis were carried out to study the seismic response of the nuclear low pressure cylinder and condenser,based on the code for seismic design of building.Seismic response characteristics of the nuclear low pressure cylinder and condenser were obtained through the seismic time history analysis and spectrum analysis.The results show that the seismic response of the nuclear low pressure cylinder and condenser presents some vibration model features of plate structures,and has a better aseismic performance than general building.
引文
[1]GB 50011—2001,建筑抗震设计规范[S].
    [2]宋锋,王元清,石永久.钢结构跃层加层的地震反应分析[J].建筑科学与工程学报,2009.3,26(1):55-61.SONG Feng,WANG Yuan-qing,SHI Yong-jiu.Seis-mic response analysis of adding extra-floors spanningexisting building with steel structure[J].Journal of Ar-chitecture and Civil Engineering,2009,26(1):55-61.
    [3]丁剑平,蹇开林,林顺洪.大型复杂钢结构厂房的抗震性能的有限元分析[J].重庆大学学报:自然科学版,2006,29(1):105-109.DING Jian-ping,JIAN Kai-lin,LIN Shun-hong.Seis-mic analysis and performance assessment of 3-D FEMof a factory building[J].Journal of Chongqing Univer-sity:Natural Science Edition,2006,29(1):105-109.