多级串联非比例阻尼隔震结构地震响应分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
建立了多级串联非比例阻尼隔震结构动力分析模型;引用分区瑞利阻尼模型将非比例阻尼矩阵分解为瑞利阻尼矩阵和体现非比例阻尼的余项阻尼矩阵,推导出结构的阻尼矩阵;并编制了MATLAB动力时程分析程序,对一实际隔震工程进行地震响应分析。结果表明:随着下部结构刚度的增加,结构的层剪力比和隔震层位移响应峰值均趋向于基础隔震结构的对应值;当下部结构为一层,且层间刚度大于上部结构底层层间刚度4~6倍时,可以近似按基础隔震结构进行动力分析。
The dynamic analysis model of multistage series non-proportion damping isolated structure is established.Citing partition of Rayleigh damping model,the non-proportional damping matrix of isolated structure is decomposed into the Rayleigh damping matrix and the surplus damping matrix reflecting non-proportional damping,and the damping matrix of multistage series non-proportion damping isolated structure is derived.Using the MATLAB software,the seismic respone analysis for a real structure is done.The results show that structure layer shear ration of the overall structure and peak displacement of isolation layer tend to correspond to value of base isolation as the lower structural mass and stiffness increased,when substructure has one layer and stiffness greater than 4 to 6 times of the upper structure stiffness of ground floor,it can approximately analyze as base isolation structure.
引文
[1]J M Kelly.The role of damping in seismic isolation[J].Earth-quake Engineering and Structure Dynamic,1999,28(1):3220-3221.
    [2]汪梦甫.非比例阻尼线性体系平稳随机地震响应计算的虚拟激励法[J].计算力学学报,2008,25(1):94-99.
    [3]周君求,彭跃社.求解弱非比例阻尼系统实模态解的阻尼矩阵摄动法[J].动力学与控制学报,2008,6(5):322-326.
    [4]杜永峰,李慧,B F Spencer,等.非比例阻尼隔震结构地震响应的实振型分解法[J].工程力学,2003,20(4):24-32.
    [5]中华人民共和国行业标准.GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
    [6]杜永峰,赵国藩.隔震结构中非经典阻尼影响及最佳阻尼比分析[J].地震工程与工程振动,2000,20(3):100-108.
    [7]Yongfeng Du,Hui Li,Billie F,et al.Effect of non-propor-tional damping on seisimic isolation[J].Journal of structural control,2002,9:205-236.
    [8]周福霖.工程结构减震控制[M].北京:地震出版社,1997.
    [9]李春锋,杜永峰,李慧.阻尼连体结构地震响应影响参数研究[J].西北地震学报,2012,34(1):33-38.
    [10]Clough R W,Penzien J.Dynamics of structures2nd ed[M].New York:McGraw-Hill,1993.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心