AP1000核电厂海水循环泵地震响应分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
针对AP1000核电厂大型双基础立式循环泵机组结构,以安全停堆地震作为设计地震载荷输入,采用响应谱法对海水循环泵在地震载荷下的动态特性和响应进行分析,并对其在安全停堆地震工况下的可运行性进行评估。结果表明,该泵的1阶自然振动频率约为17.5 Hz,其低阶振型以泵体结构的横向弯曲振动为主。根据响应谱分析与静力分析叠加的结果,地震工况下的泵体最大组合应力为173 MPa,最大变形量为4.4 mm。
To investigate the large double-base vertical mix-flow circulation pump used in AP1000 nuclear power plant,using the security shut-down earthquake load as the design seismic load,the dynamic characteristics and seismic response of sea water circulation pump under seismic load are analyzed,and the operability during SSE load is evaluated.The results demonstrated that the first natural frequency is about 17.5 Hz,and its low-order mode shapes are almost lateral bending in pump case.The combined results of response spectrum and static analysis of pump demonstrate that,the max combined stress on pump case is 173 MPa,and the max.deformation is 4.4 mm.
引文
[1]Shao Jian-hua,Shen Yong-kang.Seismic PerformanceEvaluation of Steel Frame-steel Shear Wall SystemBased on The Capacity Spectrum Method[J].Journal ofZhejiang University Science A,2008,9(3):45-49.
    [2]周文建,陈宏,闻邦椿.核电站反应堆冷却剂泵的地震响应分析[J].振动与冲击,2006,25(1):32-35.
    [3]周文霞,张继革,王德忠.核电站主泵机组地震响应谱分析及应力评定[J].原子能科学技术,2011,45(1):54-59.
    [4]付强,袁寿其,朱荣生,等.1000MW核电站SEC系统鼓型滤网抗震计算[J].核动力工程,2010,31(6):10-14.
    [5]国家核安全局.HAD102/02,核电厂的抗震设计与鉴定[S].1996.
    [6]李忠诚,杨孟嘉.AP1000抗震分析与设计特点研究[J].世界地震工程,2008,24(1):137-142.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心