基于FPGA的低功耗无缆地震仪校钟系统
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
为了降低当前无缆地震仪的功耗,并且提高其同步采集的精度,文中采用定时开启GPS,利用GPS输出的1 PPS脉冲校准采集站内置32.768 MHz恒温晶振,将校正输出的秒分频信号作为无缆地震仪采集站的同步时标。同时,利用GPS接收机输出的UTC信息校正采集站内部时钟,从而达到低功耗校钟的目的。
To reduce the power consumption and improve the synchronous acquisition accuracy of the current cable-less seismograph. This paper opened GPS regularly,used the GPS 1PPS output to correct 32. 768 MHz OCXO in acquisition station. The corrected outputs of the divided second signals served as the synchronization time scale for acquisition stations of cable-less seismograph. The universal time coordinated information from GPS receiver was used to correct the internal clock of acquisition station.The system achieved the purpose of correcting the clock in low-power consumption.
引文
[1]杨泓渊.复杂山地自定位无缆地震仪的研究与实现:[学位论文].长春:吉林大学,2009.
    [2]甘志强.几种主流地震勘探仪器性能分析探讨.石油仪器,2013,27(1):21-24.
    [3]董树文,李廷栋,陈宣华,等.我国深部探测技术与实验研究进展综述.地球物理学报,2012,55(12):3884-3901.
    [4]杨泓渊,韩立国,林君,等.无缆遥测地震仪网络同步采样技术.仪表技术与传感器,2009(3):15-18.
    [5]PEDRONI V A.VHDL数字电路设计教程.乔庐峰,王志功等译.北京:电子工业出版社,2005.
    [6]王诚,蔡海宁,吴继华.Altera FPGA/CPLD设计(基础篇),第2版.北京:人民邮电出版社,2011.
    [7]邓明,魏文博,李哲,等.海底地电探测仪器的对钟与计时技术.实验技术与管理,2003,20(5):89-92.
    [8]李泽文,曾祥君,黄智伟,等.基于高精度晶振的GPS秒时钟误差在线修正方法.电力系统自动化,2006,30(13):55-58.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心