影响张道口-1井数字化水位观测内在质量的因素
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
采用“水位调和分析(M2波计算)”程序,对天津张道口地震台张道口-1井模拟、数字化水位内在质量变化进行了对比研究。从高频干扰、周围井孔的地下水开采、仪器零漂、探头位置与观测精度变化的关系、仪器自身原因5个方面分析了影响张道口-1井数字化水位内在质量的因素,并提出了数字化水位在日常观测中的注意事项。
With the program of "the water level harmonic analysis(M2 wave computation)",we contrasted and analyzed the intrinsic quality change of the simulative and digital water level of Zhangdaokou-1 well in Tianjin seismic station.Based on 5 aspects of the high frequency interference,the under ground water mining of the bore-hole around it,null shift of the instrument,the relations of the probe position and the observation precision change,the instrument,we analyzed the intrinsic quality factors of digital water level affecting Zhangdaokou-1 well, and put up with the notice item of the digital water level in the daily observation.
引文
[1]兰陵,李新勇,夏爱国.新04号井数字化水位观测与模拟观测资料的对比分析[J].内陆地震,2004,18(4):382-384.
    [2]陈华静.京津冀晋地区水位潮汐响应函数动态特征研究[J].地震,2002,22(4):9-16.
    [3]王宝锁,王建国,吴强,等.张道口-1井水位观测精度变化分析研究[C]//赵国敏.天津市防震减灾30年纪念论文集.北京:地震出版社,2006:217-223.
    [4]车用太,鱼金子.地下流体典型异常的调查与研究[M].北京:气象出版社,2004.
    ②关于地下流体数字化观测规范的仪器检查与标定若干补充规定.中国地震局地下流体学科技术管理组,2006.