定量分析SN338数字地震仪器的特性
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
采用数值模拟定量分析方法,成功地分析和完善了SN338仪器IFP电路的特性,指出原设计参数不严密:预测时间C较大,上限参考电平Vup和下限参考电平VLow偏大,致使过零斜顶子样出现较多上溢失真点(V0(t)>8.1915V)和下溢非规格化点(V0(t)<2V).进而在微机上绘制了SN338仪器IFP电路过零斜顶子作最佳设计参数量板图,确定最佳设计参数值范围,这将明显地提高SN338仪器的保真度和量化精设.
By using of numerical modeling analytical method, the characteristics of IFP circuit in SN338 digital seismic instrument has been studied and improved successfully.Research demonstrate the inaccuracy of original designing parameters related to leaning greater of predictable time C,upper reference level VUP and lower reference level VLOW. The results of Such inaccuracy cause the appearances of under-flowing and over-flowing points for zero-passage dipping-top samples.The measuring monogram for the selection of optimum parameters for zero-passage dipping-top samples of IFP circuit in SN338 instrument has been designed in micro-COmputer.The determination of optimum disigning parameters improve the fidelity and measuring accurucy of SN338 seismic instrument obviousl.
引文
[1]吕效,两种IFP增益比较器的对比,石油地球物理勘探,增刊2,1980.[2]黄先律,地震勘探仪器,北京:地质出版社,1988.[3]TexasInstrumentsInc,DFS-VoperatingandMaintenanceManuel,1979.

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心