厦门地震台数字化水管倾斜仪观测资料分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
对厦门台DSQ型水管倾斜仪2004—2007年的观测资料作了质量评定,并对影响观测资料精度的主要干扰因素进行了分析。结果表明:1)观测资料的一般性质量评估均满足形变规范要求,达到全国先进水平;2)表征资料内在精度的噪声水平及M2波潮汐因子均方差水平同国内先进台站相比还有一定的差距;3)影响厦门台水管仪观测资料精度的主要干扰因素为海潮干扰。
The tilt data observed during 2004 to 2007 with DSQ water tube tiltmeter at Xiamen seismostation are assessed in quality and an analysis of the main disturbances of the ground tilt observations is made as well.The following conclutions are drawn: 1) The general quality of the observations meets ordinary requirements of deformation surveying standard and reaches the national advanced level.2) There is a certain gap between the noise level and the RMS error of M2 tidal factor and characterizing the inherent accuracy of the data and those observed at some advanced stations.3) The main disturbance factor impacting observations is sea tide.
引文
1中国地震局监测预报司.地形变测量[M].北京:地震出版社,2008.
    2中国地震局监测预报司.华东地区地震短期预测技术研究及综合预测专家系统[M].地震出版社,2005.
    3中国地震局.地震及前兆数字观测技术规范[M].北京:地震出版社,2001.
    4刘序俨,林继华,黄声明.福建厦门、漳州、泉州倾斜固体潮特征及其动力学解释[J].地壳形变与地震,1998,18(1):70-75.
    5熊先保,等.厦门台地倾斜观测资料中海潮干扰的综合特征[J].大地测量与地球动力学,2009,29(2):43-47.
    6黄晓华,等.台湾海峡地震定点形变的异常分析[J].华南地震,2009,29(1):96-101.