隧道–土体–地表结构相互作用体系地震响应影响因素分析
详细信息 本馆镜像全文    |  推荐本文 | | 获取馆网全文
摘要
为探讨地下结构近距离穿越地表结构时二者之间地震响应的相互影响规律,建立隧道–土体–地表框架结构相互作用体系计算模型,系统研究对该体系地震响应影响显著的参数,具体包括:隧道的直径和埋深、土体的分层特性、框架结构的高宽比及其与隧道圆心的间距、输入地震波特性等。计算分析表明:(1)隧道对体系自振特性影响并不显著,但地表框架结构则显著改变了体系的频率特征;(2)隧道对地表框架结构地震响应的影响主要与隧道的半径相关,较大的隧道半径可阻隔地震波的传播,从而起到一定的减震功能;(3)由于考虑的框架结构质量相对较轻,地表框架结构对隧道地震响应的影响不显著;(4)由于地震波频谱成分及结构自身频率的影响,不同地震波对体系地震响应的影响十分显著;(5)土的分层特性改变了土体的刚度,因而也影响了体系的地震响应。研究成果可为初步定性确定地下结构与临近地表结构地震响应的相互影响提供参考。
In order to investigate the mutual influence of the seismic responses from the underground structure and above ground structure,a computation model containing a system of the tunnel,the ground soil and the adjacent structures was established. The key factors influencing the seismic responses of the system were studied,including the depth and radius of tunnel,the features of layered soils,the height to width ratio of the super structure,the distance from the super structure to the axis of tunnel and the characteristics of the input seismic waves. The calculated results showed that the existence of tunnel had almost no influence on the natural frequency of the system,while the super structure had a significant influence on the frequency character of the system. The main factor of tunnel influencing the super structure was the radius of tunnel because the tunnel with larger radius blocked more prominently the propagation of seismic wave leading to some degree of shock absorption. Theinfluence of super structure on the seismic response tunnel was insignificant because the weight of the super structure considered in the paper was very light. The characteristics of input seismic waves had significant effect on the seismic response of the system due to the frequency contents and frequencies of the super structure. The seismic responses of the system were influenced by the soil properties.
引文
[1]DRAVINSKI M.Ground motion amplification due to elastic inclusions in a halfspace[J].Earthquake Engineering and Structural Dynamics,1983,11(3):313–335.
    [2]PAIS A,KAUSEL E.Effect of underground tunnel on seismic motions in Mexico city[R].Cambridge:Department of Civil Engineering,Massachusetts Institute of Technology,1989.
    [3]SMERZINI1 C,AVILES J,PAOLUCCI R,et al.Effect of underground cavities on surface earthquake ground motion under SH wave propagation[J].Earthquake Engineering and Structure Dynamics,2009,38(12):1 441–1 460.
    [4]梁建文,张浩,VINCENT W L.地下洞室群对地面运动的影响[J].土木工程学报,2005,38(2):106–114.(LIANG Jianwen,ZHANG Hao,VINCENT W L.Effect of underground group cavities on ground surface motion[J].China Civil Engineering Journal,2005,38(2):106–114.(in Chinese))
    [5]梁建文,张季,巴振宁.层状半空间中洞室群对地震动的时域放大作用[J].土木工程学报,2012,45(增1):152–157.(LIANG Jianwen,ZHANG Ji,BA Zhenning.Time-domain amplification of seismic ground motion by group cavities in layered half-space[J].China Civil Engineering Journal,2012,45(Supp.1):152–157.(in Chinese))
    [6]陈健云,何伟,徐强,等.地下结构对场地土和地表建筑地震响应的影响分析[J].大连理工大学学报,2012,52(3):393–398.(CHEN Jianyun,HE Wei,XU Qiang,et al.Analysis for effect of underground structure on seismic response of ground and adjacent surface buildings[J].Journal of Dalian University of Technology,2012,52(3):393–398.(in Chinese))
    [7]郭靖,陈健云.均质地基地铁车站对临近建筑层间位移角的影响[J].湖南大学学报:自然科学版,2013,40(8):40–45.(GUO Jing,CHEN Jianyun.Influence of subway station buried in homogeneous foundations on the inter-story drift of adjacent structures[J].Journal of Hunan University:Natural Science,2013,40(8):40–45.(in Chinese))
    [8]李方杰.邻近建筑对地铁结构地震反应的影响研究[博士学位论文][D].北京:中国地震局地球物理研究所,2009.(LI Fangjie.Influence of nearby ground building on seismic response of subway structure[Ph.D.Thesis][D].Beijing:Institute of Geophysics,China Earthquake Administration,2009.(in Chinese))
    [9]陈国兴,庄海洋,徐烨.软弱地基浅埋隧洞对场地设计地震动的影响[J].岩土工程学报,2004,26(6):739–744.(CHEN Guoxing,ZHUANG Haiyang,XU Ye.A study on influence of excavated shallow tunnel on design parameters of ground motion in the soft site[J].Chinese Journal of Geotechnical Engineering,2004,26(6):739–744.(in Chinese))
    [10]MROUEH H,SHAHROUR I.A full 3D finite element analysis of tunneling-adjacent structures interaction[J].Computers and Geotechnics,2003,30(3):245–253.
    [11]楼梦麟,潘旦光,范立础.土层地震反应分析中侧向人工边界的影响[J].同济大学学报,2003,31(7):757–761.(LOU Menglin,PAN Danguang,FAN Lichu.Effect of vertical artificial boundary on seismic response of soil layer[J].Journal of Tongji University,2003,31(7):757–761.(in Chinese))
    [12]王国波,于艳丽,何卫.下穿隧道–土–地表邻近框架结构相互作用体系地震响应初步分析[J].岩土工程学报,2014,36(2):334–338.(WANG Guobo,YU Yanli,HE Wei.Seismic response of interaction system of underlying tunnels,soils and adjacent frame structures[J].Chinese Journal of Geotechnical Engineering,2014,36(2):334–338.(in Chinese))
    [13]徐炳伟.大型复杂结构–桩–土振动台模型试验研究[博士学位论文][D].天津:天津大学,2009.(XU Bingwei.Shaking table test studying large-scale soil-pile-complex structure interaction[Ph.D.Thesis][D].Tianjin:Tianjin University,2009.(in Chinese))
    [14]邹德高,徐斌,孔宪京.瑞利阻尼系数确定方法对高土石坝地震反应的影响研究[J].岩土力学,2011,32(3):797–803.(ZOU Degao,XU Bin,KONG Xianjing.Study of influence of different methods for calculating Rayleigh damping coefficient on high earth-rock dam seismic response[J].Rock and Soil Mechanics,2011,32(3):797–803.(in Chinese))
    [15]中华人民共和国国家标准编写组.GB50909—2014城市轨道交通结构抗震设计规范[S].北京:中国计划出版社,2014.(The National Standards Compilation Group of People's Republic of China.GB50909—2014 Code for seismic design of urban rail transit structures[S].Beijing:China Planning Press,2014.(in Chinese))
    [16]中华人民共和国国家标准编写组.GB 50010—2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.(The National Standards Compilation Group of People's Republic of China.GB 50010—2010Code for seismic design of buildings[S].Beijing:China Architecture and Building Press,2010.(in Chinese))

版权所有:© 2023 中国地质图书馆 中国地质调查局地学文献中心